• IEC 62220-1-1:2015

    Current The latest, up-to-date edition.

    Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French

    Published date:  12-03-2015

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements
    5 Corrections of RAW DATA
    6 Determination of the DETECTIVE QUANTUM EFFICIENCY
    7 Format of conformance statement
    8 Accuracy
    Annex A (normative) - Determination of LAG EFFECTS
    Annex B (informative) - Calculation of the input NOISE
            POWER SPECTRUM
    Bibliography
    Index of defined terms used in this particular standard

    Abstract - (Show below) - (Hide below)

    IEC 62220-1-1:2015 specifies the method for the determination of the DETECTIVE QUANTUM EFFICIENCY (DQE) of DIGITAL X-RAY IMAGING DEVICES as a function of AIR KERMA and of SPATIAL FREQUENCY for the working conditions in the range of the medical application as specified by the MANUFACTURER. The intended users of this part of IEC 62220 are manufacturers and well equipped test laboratories. This first edition of IEC 62220-1-1 cancels and replaces IEC 62220-1:2003. It constitutes a technical revision of IEC 62220-1:2003 and assures a better alignment with the other parts of the IEC 62220 series. The main changes are as follows:
    - necessary modifications have been applied as a consequence of taking into account IEC 61267:2005. This influences HVL values and SNRin2;
    - the method for the determination of LAG EFFECTS now considers lag and ghosting compensation;
    - as part of the MTF determination, the method of obtaining the final averaged MTF has been restricted (only averaging of the ESF is allowed);
    - a description of (optionally) obtaining the diagonal (45°) MTF and NPS has been added.

    General Product Information - (Show below) - (Hide below)

    Committee TC 62/SC 62B
    Development Note Supersedes IEC 62220-1. Stability date: 2017. (03/2015)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    16/30216785 DC : 0 BS EN 62667 - MEDICAL ELECTRICAL EQUIPMENT - MEDICAL LIGHT ION BEAM EQUIPMENT - PERFORMANCE CHARACTERISTICS
    I.S. EN IEC 62667:2018 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL LIGHT ION BEAM EQUIPMENT - PERFORMANCE CHARACTERISTICS
    IEC 60601-2-43:2010+AMD1:2017 CSV Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
    16/30342399 DC : 0 BS EN 60601-2-43:2010/A1 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES
    EN 60601-2-43:2010/A1:2018 MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES (IEC 60601-2-43:2010/A1:2017)
    BS EN IEC 62667:2018 Medical electrical equipment. Medical light ion beam equipment. Performance characteristics
    17/30341818 DC : 0 BS EN 60601-2-54 ED 1.0/A2 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY
    EN IEC 62667:2018 Medical electrical equipment - Medical light ion beam equipment - Performance characteristics
    I.S. EN 60601-2-43:2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
    ISO 15529:2010 Optics and photonics Optical transfer function Principles of measurement of modulation transfer function (MTF) of sampled imaging systems
    IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
    IEC 62220-1-2:2007 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography
    IEC 60601-2-54:2009+AMD1:2015 CSV Medical electrical equipment - Part 2-54: Particular requirementsfor the basic safety and essential performance of X-ray equipmentfor radiography and radioscopy
    ISO 12233:2017 Photography — Electronic still picture imaging — Resolution and spatial frequency responses
    IEC 61262-5:1994 Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 5: Determination of the detective quantum efficiency
    IEC 62220-1-3:2008 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-3: Determination of the detective quantum efficiency - Detectors used in dynamic imaging
    IEC 61267:2005 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective