• EN ISO 12417-1:2015

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Cardiovascular implants and extracorporeal systems - Vascular device-drug combination products - Part 1: General requirements (ISO 12417-1:2015)

    Available format(s): 

    Superseded date:  28-02-2024

    Language(s): 

    Published date:  14-10-2015

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Intended performance
    5 Design attributes
    6 Materials
    7 Design evaluation
    8 Manufacturing
    9 Sterilization
    10 Packaging
    11 Information supplied by the manufacturer
    Annex A (informative) - Definitions of potential clinical
            and technical events
    Annex B (informative) - Local information regarding
            submission issues for VDDCPs
    Bibliography
    Annex ZA (informative) Relationship between this
             European Standard and the Essential
             Requirements of EU Directive 93/42/EEC
             on medical devices

    Abstract - (Show below) - (Hide below)

    ISO 12417-1:2015 specifies requirements for vascular device-drug combination products (VDDCPs) based upon current technical and medical knowledge. VDDCPs are medical devices with various clinical indications for use in the human vascular blood system. A VDDCP incorporates, as an integral part, substance(s) which, if used separately, can be considered to be a medicinal substance or product (drug substance, drug product) but the action of the medicinal substance is ancillary to that of the device and supports the primary mode of action (PMOA) of the device. With regard to safety, this part of ISO 12417 outlines requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging, and information supplied by the manufacturer. For implanted products, this International Standard should be considered as a supplement to ISO 14630, which specifies general requirements for the performance of non-active surgical implants. This International Standard should also be considered as a supplement to relevant device-specific standards, such as the ISO 25539‑series specifying requirements for endovascular devices. Requirements listed in this part of ISO 12417 also address VDDCPs that are not permanent implants.NOTE Due to variations in the design of combination products covered by this part of ISO 12417 and due to the relatively recent development of some of these combination products, acceptable standardized in vitro test results and clinical study results are not always available. As further scientific and clinical data become available, appropriate revision of this part of ISO 12417 might be necessary.Delivery systems or parts of the delivery system are included in the scope of this part of ISO 12417, if they comprise an integral component of the vascular device and if they are drug-covered (e.g. drug-covered balloon catheters and drug-covered guidewires).Devices whose PMOA is to provide a conduit for delivery of a drug, are excluded from the scope of this part of ISO 12417 (e.g. infusion catheters), unless they contain a drug component that is intended to have an ancillary action to the device part (e.g. antimicrobial coated infusion catheter).Procedures and devices used prior to and following the introduction of the VDDCP (e.g. balloon angioplasty devices) are excluded from the scope of this part of ISO 12417 if they do not affect the drug-related aspects of the device.ISO 12417-1:2015 is not comprehensive with respect to the pharmacological evaluation of VDDCPs. Some information on the requirements of different national and regional authorities is given in Annex B.Absorbable components of VDDCPs (e.g. coatings) are addressed by this part of ISO 12417 in their connection with drug-related aspects of the device. Degradation and other time-dependent aspects of absorbable implants and coatings are not completely addressed by this part of ISO 12417.NOTE See also ISO/TS 17137 and ASTM F3036-13.ISO 12417-1:2015 does not address issues associated with viable or non-viable biological materials such as tissues, cells, or proteins.ISO 12417-1:2015 does not address issues associated with active surgical implants (i.e. implants that require power not generated by the human body or gravity).

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 285
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Superseded

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 11070:2014 Sterile single-use intravascular introducers, dilators and guidewires
    ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
    ISO 25539-2:2012 Cardiovascular implants Endovascular devices Part 2: Vascular stents
    CFR 21(PTS200-299) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 200-299
    ISO 14160:2011 Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical devices
    ISO 16054:2000 Implants for surgery Minimum data sets for surgical implants
    ISO 13960:2010 Cardiovascular implants and extracorporeal systems Plasmafilters
    ISO 5840:2005 Cardiovascular implants Cardiac valve prostheses
    EN 556-2:2015 Sterilization of medical devices - Requirements for medical devices to be designated 'STERILE" - Part 2: Requirements for aseptically processed medical devices
    ISO 10555-2:1996 Sterile, single-use intravascular catheters Part 2: Angiographic catheters
    ISO 7198:2016 Cardiovascular implants and extracorporeal systems — Vascular prostheses — Tubular vascular grafts and vascular patches
    ASTM F 2503 : 2013 : REDLINE Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment
    ISO 17475:2005 Corrosion of metals and alloys Electrochemical test methods Guidelines for conducting potentiostatic and potentiodynamic polarization measurements
    ISO 13485:2016 Medical devices Quality management systems Requirements for regulatory purposes
    ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
    CFR 21(PTS800-1299) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 800-1299
    ISO 10993-2:2006 Biological evaluation of medical devices — Part 2: Animal welfare requirements
    ISO 25539-1:2017 Cardiovascular implants — Endovascular devices — Part 1: Endovascular prostheses
    ISO 14630:2012 Non-active surgical implants General requirements
    ISO 5841-2:2014 Implants for surgery Cardiac pacemakers Part 2: Reporting of clinical performance of populations of pulse generators or leads
    ISO/TR 14283:2004 Implants for surgery Fundamental principles
    ISO/TS 17137:2014 Cardiovascular implants and extracorporeal systems Cardiovascular absorbable implants
    ASTM F 2052 : 2015 : REDLINE Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
    ISO/TS 15539:2000 Cardiovascular implants Endovascular prostheses
    ISO 13781:2017 Implants for surgery — Homopolymers, copolymers and blends on poly(lactide) — In vitro degradation testing
    ISO 7199:2016 Cardiovascular implants and artificial organs Blood-gas exchangers (oxygenators)
    ASTM F 2213 : 2017 : REDLINE Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment
    ISO 10993-7:2008 Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals
    ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
    ISO 10555-3:2013 Intravascular catheters — Sterile and single-use catheters — Part 3: Central venous catheters
    CFR 21(PTS1-99) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 1-99
    ISO 10555-1:2013 Intravascular catheters — Sterile and single-use catheters — Part 1: General requirements
    ISO 15814:1999 Implants for surgery Copolymers and blends based on polylactide In vitro degradation testing
    ISO 25539-3:2011 Cardiovascular implants Endovascular devices Part 3: Vena cava filters
    ISO 14155:2011 Clinical investigation of medical devices for human subjects Good clinical practice
    ISO 16428:2005 Implants for surgery — Test solutions and environmental conditions for static and dynamic corrosion tests on implantable materials and medical devices
    ISO 14971:2007 Medical devices Application of risk management to medical devices
    ISO 11607-1:2006 Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems
    ISO 15223-1:2016 Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements
    ASTM D 638 : 2014 : REDLINE Standard Test Method for Tensile Properties of Plastics
    ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
    ISO 10555-4:2013 Intravascular catheters — Sterile and single-use catheters — Part 4: Balloon dilatation catheters
    ISO 16429:2004 Implants for surgery — Measurements of open-circuit potential to assess corrosion behaviour of metallic implantable materials and medical devices over extended time periods
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective