EN ISO 16017-2:2003
Current
The latest, up-to-date edition.
Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ISO 16017-2:2003)
15-05-2003
Foreword
1 Scope
2 Normative references
3 Principle
4 Reagents and materials
5 Apparatus
6 Sample tube conditioning
7 Sampling
8 Procedure
8.1 Safety precautions
8.2 Desorption and analysis
8.3 Calibration
8.4 Determination of sample concentration
8.5 Determination of desorption efficiency
8.6 Calibration of uptake rate
9 Calculations
9.1 Mass concentration of analyte
9.2 Volume concentration of analyte
9.3 Uptake rates
10 Interferences
11 Performance characteristics
12 Test report
13 Quality control
Annex A (informative) Operating principles of diffusive
sampling
Annex B (informative) Description of sorbent types
Annex C (informative) Guidance on sorbent selection
Annex D (informative) Guidance on sorbent use
Annex E (informative) Summary of data on overall uncertainty,
precision, bias and storage
Bibliography
ISO 16017-2:2003 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to indoor, ambient and workplace air.ISO 16017-2:2003 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, ester, glycol ethers, ketones and alcohols. A number of sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compounds generally require derivatisation; very low boiling compounds are only partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds are fully retained by the sorbents, but may only be partially recovered.ISO 16017-2:2003 is applicable to the measurement of airborne vapours of VOCs in a concentration range of approximately 0,002 mg/m3 to 100 mg/m3 individual organic for an exposure time of 8 h, or 0,3 g/m3 to 300 g/m3 individual organic for an exposure time of four weeks.The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically sub-nanogram for well-conditioned Tenax GR and carbonaceous sorbents, carbonized molecular sieves and pure charcoals; at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers.
Committee |
CEN/TC 264
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
SS-EN ISO 16017-2 : 2003 | Identical |
BS EN ISO 16017-2:2003 | Identical |
I.S. EN ISO 16017-2:2003 | Identical |
PN EN ISO 16017-2 : 2008 | Identical |
ISO 16017-2:2003 | Identical |
NS EN ISO 16017-2 : 1ED 2003 | Identical |
UNE-EN ISO 16017-2:2004 | Identical |
NF EN ISO 16017-2 : 2003 | Identical |
DIN EN ISO 16017-2:2003-09 | Identical |
SN EN ISO 16017-2 : 2003 | Identical |
NEN EN ISO 16017-2 : 2003 | Identical |
NBN EN ISO 16017-2 : 2003 | Identical |
UNI EN ISO 16017-2 : 2004 | Identical |
06/30155808 DC : DRAFT SEP 2006 | BS EN 13999-4 - ADHESIVES - SHORT-TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
BS EN 13528-3:2003 | Ambient air quality. Diffusive samplers for the determination of concentrations of gases and vapours. Requirements and test methods Guide to selection, use and maintenance |
BS EN 14662-4:2005 | Ambient air quality. Standard method for measurement of benzene concentrations Diffusive sampling followed by thermal desorption and gas chromatography |
I.S. EN 13999-4:2007 | ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
I.S. EN 838:2010 | WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS |
EN 13528-3:2003 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 3: Guide to selection, use and maintenance |
16/30332593 DC : 0 | BS EN 15759-2 - CONSERVATION OF CULTURAL HERITAGE - INDOOR CLIMATE - PART 2: VENTILATION TO PROTECT HERITAGE BUILDINGS AND COLLECTIONS |
I.S. EN 15759-2:2018 | CONSERVATION OF CULTURAL HERITAGE - INDOOR CLIMATE - PART 2: VENTILATION MANAGEMENT FOR THE PROTECTION OF CULTURAL HERITAGE BUILDINGS AND COLLECTIONS |
UNI EN 838 : 2010 | WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS |
VDI 4300 Blatt 9:2005-08 | Measurement of indoor air pollution - Measurement strategy for carbon dioxide (CO) |
EN 15759-2:2018 | Conservation of cultural heritage - Indoor climate - Part 2: Ventilation management for the protection of cultural heritage buildings and collections |
UNI EN 13999-4 : 2009 | ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
DIN EN 13999-4:2009-08 | ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
DIN EN 838:2010-05 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
BS EN 13999-4 : 2007 | ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 4: DETERMINATION OF VOLATILE DIISOCYANATES |
BS EN 838:2010 | Workplace exposure. Procedures for measuring gases and vapours using diffusive samplers. Requirements and test methods |
EN 14662-4:2005 | Ambient air quality - Standard method for measurement of benzene concentrations - Part 4: Diffusive sampling followed by thermal desorption and gas chromatography |
EN 838:2010 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
EN 13999-4:2007+A1:2009 | Adhesives - Short term method for measuring the emission properties of low-solvent or solvent-free adhesives after application - Part 4: Determination of volatile diisocyanates |
DIN EN 14662-4:2005-08 | AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY |
DIN EN 13528-3:2004-04 | Ambient air quality - Diffuse samplers for the determination of concentrations of gases and vapours - Part 3: Guide to selection, use and maintenance |
VDI 2119 Blatt 4:1997-08 | Measurement of Particulate Precipitations - Microscopic differentiation and size fractionated determination of particle deposition on adhesive collection plates - Sigma-2 sampler |
EN 838:2010 | Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
EN 13528-1:2002 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 1: General requirements |
EN 13528-2:2002 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 2: Specific requirements and test methods |
ISO 6145-5:2009 | Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 5: Capillary calibration devices |
ISO 16000-1:2004 | Indoor air — Part 1: General aspects of sampling strategy |
ISO 6145-4:2004 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method |
ISO 6145-3:1986 | Gas analysis Preparation of calibration gas mixtures Dynamic volumetric methods Part 3: Periodic injections into a flowing gas stream |
ISO 6145-1:2003 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration |
ISO 6141:2015 | Gas analysis Contents of certificates for calibration gas mixtures |
ISO 6145-6:2017 | Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.