1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Risk management
6 General design requirements
7 Fuel supply to the fuelling station
8 Dryer
9 Compressors
10 Buffer storage
11 Dispensers
12 Gas odorization
13 Pipework
14 Electrical
15 Instrumentation and control system
16 Emergency shutdown
17 Indoor fuelling
18 Testing and commissioning
19 Operation
20 Inspection and maintenance
Annex A (informative) - Examples of hazardous zone classification
Annex B (normative) - Separation distances
Annex C (informative) - Fuelling procedures
Annex D (informative) - Emergency instructions example
Annex E (informative) - Example of fuelling station periodic
        inspection and maintenance
Bibliography

ISO 16923:2016 covers the design, construction, operation, inspection and maintenance of stations for fuelling compressed natural gas (CNG) to vehicles, including equipment, safety and control devices.ISO 16923:2016 also applies to portions of a fuelling station where natural gas is in a gaseous state and dispensing CNG derived from liquefied natural gas (LCNG) according to ISO 16924.ISO 16923:2016 applies to fuelling stations supplied with natural gas as defined in local applicable gas composition regulations or ISO 13686. It also applies to other gases meeting these requirements including biomethane, upgraded coal-bed methane (CBM) and gas supplies coming from LNG vaporization (on-site or off-site).ISO 16923:2016 includes all equipment for downstream gas supply connection (i.e. point of separation between the CNG fuelling station piping and the pipeline network). Fuelling station nozzles are not defined in this document.ISO 16923:2016 covers fuelling stations with the following characteristics:- slow fill;- fast fill;- private access;- public access (self-service or assisted);- fuelling stations with fixed storage;- fuelling stations with mobile storage (daughter station);- multi-fuel stations.ISO 16923:2016 is not applicable to domestic CNG fuelling devices without buffer storage.NOTE ISO 16923:2016 is based on the condition that the gas entering the fuelling station is odorized. For unodorized gas fuelling stations, additional safety requirements are included in Clause 10.

Committee
CEN/TC 326
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.