• Shopping Cart
    There are no items in your cart

EN ISO 8253-1:2010

Current

Current

The latest, up-to-date edition.

Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010)

Published date

01-11-2010

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General aspects of audiometric measurements
5 Preparation and instruction of test subjects before
   audiometric testing and positioning of transducers
6 Air conduction hearing threshold level determinations
   using fixed-frequency audiometry
7 Air conduction hearing threshold level determinations
   using sweep-frequency audiometry
8 Bone conduction hearing threshold audiometry
9 Screening audiometry
10 Audiograms
11 Permissible ambient noise
12 Maintenance and calibration of audiometric equipment
Annex A (informative) - Measurement uncertainty
Bibliography

ISO 8253-1:2010 specifies procedures and requirements for pure-tone air conduction and bone conduction threshold audiometry. For screening purposes, only pure-tone air conduction audiometric test methods are specified. It is possible that the procedures are not appropriate for special populations, e.g. very young children.ISO 8253-1:2010 does not cover audiometric procedures to be carried out at levels above the hearing threshold levels of the subjects.Procedures and requirements for speech audiometry, electrophysiological audiometry, and where loudspeakers are used as a sound source are not specified.

Committee
CEN/TC 211
DevelopmentNote
Supersedes EN 26189. (11/2010)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

09/30198066 DC : 0 BS EN 15927 - SERVICES OFFERED BY HEARING AID PROFESSIONALS
NF EN 15927 : 2010 SERVICES OFFERED BY HEARING AID PROFESSIONALS
I.S. EN 15927:2010 SERVICES OFFERED BY HEARING AID PROFESSIONALS
CEI EN 60645-1 : 2016 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AUDIOMETRY
UNI EN 15927 : 2010 SERVICES OFFERED BY HEARING AID PROFESSIONALS
EN 15927:2010 Services offered by hearing aid professionals
UNE-EN 15927:2011 Services offered by hearing aid professionals
BS EN 60645-1:2017 Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry
BS EN 15927:2010 Services offered by hearing aid professionals
I.S. EN 60645-1:2017 ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
UNE-EN 60645-1:2015 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry
EN 60645-1:2017 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry

IEC 60318-4:2010 Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts
IEC 60318-6:2007 Electroacoustics - Simulators of human head and ear - Part 6: Mechanical coupler for the measurement on bone vibrators
ISO 389-4:1994 Acoustics Reference zero for the calibration of audiometric equipment Part 4: Reference levels for narrow-band masking noise
ISO 389-7:2005 Acoustics Reference zero for the calibration of audiometric equipment Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions
IEC 60318-3:2014 Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry
IEC 60645-1:2017 Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
ISO 4869-1:1990 Acoustics Hearing protectors Part 1: Subjective method for the measurement of sound attenuation
ISO 389-8:2004 Acoustics — Reference zero for the calibration of audiometric equipment — Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones
ISO 389-5:2006 Acoustics Reference zero for the calibration of audiometric equipment Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz
IEC 60318-5:2006 Electroacoustics - Simulators of human head and ear - Part 5: 2 cm<sup>3</sup> coupler for the measurement of hearing aids and earphones coupled to the ear by means of ear inserts
ISO 389-1:1998 Acoustics Reference zero for the calibration of audiometric equipment Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones
ISO 389-2:1994 Acoustics Reference zero for the calibration of audiometric equipment Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones
ISO 389-3:2016 Acoustics Reference zero for the calibration of audiometric equipment Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators
IEC 61260:1995 Electroacoustics - Octave-band and fractional-octave-band filters
IEC 60318-1:2009 Electroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.