EN ISO 8990:1996
Current
The latest, up-to-date edition.
Thermal insulation - Determination of steady-state thermal transmission properties - Calibrated and guarded hot box (ISO 8990:1994)
21-08-1996
Section 1 General
1.1 Scope
1.2 Normative reference
1.3 Definitions
1.4 Symbols, units and relationships
1.5 Principle
1.6 Limitations and sources of errors
Section 2 Apparatus
2.1 Introduction
2.2 Design requirements
2.3 Metering box
2.4 Guard box
2.5 Specimen frame
2.6 Cold side chamber
2.7 Temperature measurements
2.8 Instrumentation
2.9 Performance evaluation and calibration
Section 3 Test procedure
3.1 Introduction
3.2 Conditioning of specimen
3.3 Specimen selection and mounting
3.4 Test conditions
3.5 Measurement periods
3.6 Calculations
3.7 Test report
Annexes
A Heat transfer at surfaces and environmental temperatures
B Bibliography
Lays down the principles for the design of the apparatus and minimum requirement that shall be met for determination of the laboratory steady-state thermal transmission properties of building components and similar components for industrial use. Does not specify a particular design. Describes also the apparatus, measurement technique and necessary data reporting. Primarily intended for laboratory measurements of large, inhomogeneous specimens. Does not provide for measurements where there is mass transfer through the specimen during the test.
Committee |
CEN/TC 89
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
ISO 8990:1994 | Identical |
NBN EN ISO 8990 : 1996 | Identical |
NEN EN ISO 8990 : 1997 | Identical |
NS EN ISO 8990 : 1ED 1997 | Identical |
I.S. EN ISO 8990:1997 | Identical |
PN EN ISO 8990 : 1998 | Identical |
SN EN ISO 8990 : 1996 | Identical |
UNI EN ISO 8990 : 1999 | Identical |
SS-EN ISO 8990 :1996 | Identical |
BS EN ISO 8990:1996 | Identical |
UNE-EN ISO 8990:1997 | Identical |
NF EN ISO 8990 : 1996 | Identical |
DIN EN ISO 8990:1996-09 | Identical |
17/30354239 DC : 0 | BS EN 13369 - COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
10/30228898 DC : 0 | BS EN 1745 - MASONRY AND MASONRY PRODUCTS - METHODS FOR DETERMINING THERMAL PROPERTIES |
I.S. CEN TR 14613:2004 | THERMAL PERFORMANCE OF BUILDING MATERIALS AND COMPONENTS - PRINCIPLES FOR THE DETERMINATION OF THERMAL PROPERTIES OF MOIST MATERIALS AND COMPONENTS |
I.S. EN 16012:2012 | THERMAL INSULATION FOR BUILDINGS - REFLECTIVE INSULATION PRODUCTS - DETERMINATION OF THE DECLARED THERMAL PERFORMANCE |
DIN EN 12412-4:2003-11 | Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 4: Roller shutter boxes; German version EN 12412-4:2003 |
DIN EN 12412-2:2003-11 | Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames; German version EN 12412-2:2003 |
BS EN 1934:1998 | Thermal performance of buildings. Determination of thermal resistance by hot box method using heat flow meter. Masonry |
EN 12412-4:2003 | Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 4: Roller shutter boxes |
CEN/TR 14613:2003 | Thermal performance of building materials and components - Principles for the determination of thermal properties of moist material and components |
EN 12412-2:2003 | Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames |
DIN EN 16012:2015-05 | Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance (includes Amendment A1:2015) |
08/30178840 DC : DRAFT AUG 2008 | BS EN 15037-3 - PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 3: CLAY BLOCKS |
10/30218985 DC : DRAFT JUNE 2010 | BS EN 13369 - COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
15/30301583 DC : 0 | BS EN 16863 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE REFLECTIVE INSULATION PRODUCTS (RI) - SPECIFICATION |
UNI EN 15037-3 : 2011 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 3: CLAY BLOCKS |
BS EN 15037-3 : 2009 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 3: CLAY BLOCKS |
BS EN 13369:2013 | Common rules for precast concrete products |
I.S. EN 13369:2013 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
UNE-EN 16012:2013 | Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance |
PD CEN/TR 14613:2003 | Thermal performance of building materials and components. Principles for the determination of thermal properties of moist materials andcomponent s |
00/108536 DC : 0 | PREN 14064-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
UNI EN 13369 : 2013 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
PREN 13369 : DRAFT 2017 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
UNE-EN 13369:2013 | Common rules for precast concrete products |
DIN EN 13369:2013-08 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
BS EN 1946-4:2000 | Measurements by hot box methods |
UNE-EN 15037-3:2010 | Precast concrete products - Beam-and-block floor systems - Part 3: Clay blocks |
EN 1946-4:2000 | Thermal performance of building products and components - Specific criteria for the assessment of laboratories measuring heat transfer properties - Part 4: Measurements by hot box methods |
EN 15037-3:2009+A1:2011 | Precast concrete products - Beam-and-block floor systems - Part 3: Clay blocks |
EN 16012:2012+A1:2015 | Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance |
EN 1934:1998 | Thermal performance of buildings - Determination of thermal resistance by hot box method using heat flow meter - Masonry |
05/30128661 DC : 0 | EN 13779 - VENTILATION FOR NON RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS |
BS EN 16012 : 2012 | THERMAL INSULATION FOR BUILDINGS - REFLECTIVE INSULATION PRODUCTS - DETERMINATION OF THE DECLARED THERMAL PERFORMANCE |
DIN EN 15037-3:2011-07 | Precast concrete products - Beam-and-block floor systems - Part 3: Clay blocks (includes Amendment A1:2011) |
I.S. EN 15037-3:2009 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 3: CLAY BLOCKS |
I.S. EN 13369:2018 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
EN 13369:2018 | Common rules for precast concrete products |
BS EN 12412-4:2003 | Thermal performance of windows, doors and shutters. Determination of thermal transmittance by hot box method Roller shutter boxes |
BS EN 12412-2:2003 | Thermal performance of windows, doors and shutters. Determination of thermal transmittance by hot box method Frames |
ISO 8302:1991 | Thermal insulation — Determination of steady-state thermal resistance and related properties — Guarded hot plate apparatus |
ISO 8301:1991 | Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter apparatus |
ISO 9288:1989 | Thermal insulation — Heat transfer by radiation — Physical quantities and definitions |
BS 874:1973 | Methods for determining thermal insulating properties with definitions of thermal insulating terms |
BS EN ISO 7345:1996 | Thermal insulation. Physical quantities and definitions |
ISO 9251:1987 | Thermal insulation Heat transfer conditions and properties of materials Vocabulary |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.