08/30181539 DC : DRAFT APR 2008
|
BS EN ISO 12574-3 - THERMAL INSULATION - CELLULOSE-FIBRE LOOSE-FILL FOR HORIZONTAL APPLICATIONS IN VENTILATED ROOF SPACES - PART 3: TEST METHODS |
93/105958 DC : DRAFT JULY 1993
|
PREN 1098 - MEASURING METHOD FOR THE DETERMINATION OF THE THERMAL TRANSMITTANCE OF MULTIPLE GLAZING (U-VALUE) - CALIBRATED AND GUARDED HOT BOX METHOD |
13/30279556 DC : 0
|
BS ISO 9869-1 - THERMAL INSULATION - BUILDING ELEMENTS - IN-SITU MEASUREMENT OF THERMAL RESISTANCE AND THERMAL TRANSMITTANCE - PART 1: HEAT FLOW METER METHOD |
DIN EN 15037-3:2011-07
|
Precast concrete products - Beam-and-block floor systems - Part 3: Clay blocks (includes Amendment A1:2011) |
I.S. EN 16012:2012
|
THERMAL INSULATION FOR BUILDINGS - REFLECTIVE INSULATION PRODUCTS - DETERMINATION OF THE DECLARED THERMAL PERFORMANCE |
ISO 19467:2017
|
Thermal performance of windows and doors — Determination of solar heat gain coefficient using solar simulator |
15/30301583 DC : 0
|
BS EN 16863 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE REFLECTIVE INSULATION PRODUCTS (RI) - SPECIFICATION |
DIN EN ISO 12567-1:2010-12
|
Thermal performance of windows and doors - Determination of thermal transmittance by the hot-box method - Part 1: Complete windows and doors (ISO 12567-1:2010) |
DIN EN ISO 10456:2010-05
|
Building materials and products - Hygrothermal properties - Tabulated design values and procedures for determining declared and design thermal values (ISO 10456:2007 + Cor. 1:2009); German version EN ISO 10456:2007 + AC:2009 |
BS EN 1934:1998
|
Thermal performance of buildings. Determination of thermal resistance by hot box method using heat flow meter. Masonry |
EN ISO 10456:2007/AC:2009
|
BUILDING MATERIALS AND PRODUCTS - HYGROTHERMAL PROPERTIES - TABULATED DESIGN VALUES AND PROCEDURES FOR DETERMINING DECLARED AND DESIGN THERMAL VALUES |
EN 12412-4:2003
|
Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 4: Roller shutter boxes |
CEN/TR 14613:2003
|
Thermal performance of building materials and components - Principles for the determination of thermal properties of moist material and components |
EN 12412-2:2003
|
Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames |
DIN EN 16012:2015-05
|
Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance (includes Amendment A1:2015) |
17/30354239 DC : 0
|
BS EN 13369 - COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
00/102700 DC : DRAFT MAR 2000
|
ISO/DIS 15099 - THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHADING DEVICES - DETAILED CALCULATIONS |
10/30218985 DC : DRAFT JUNE 2010
|
BS EN 13369 - COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
09/30196724 DC : 0
|
BS ISO 18292 - ENERGY PERFORMANCE OF FENESTRATION SYSTEMS - CALCULATION PROCEDURE |
08/30178840 DC : DRAFT AUG 2008
|
BS EN 15037-3 - PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 3: CLAY BLOCKS |
17/30319129 DC : DRAFT APR 2017
|
BS ISO 9869-2 - THERMAL INSULATION - BUILDING ELEMENTS - IN-SITU MEASUREMENT OF THERMAL RESISTANCE AND THERMAL TRANSMITTANCE - PART 2: INFRARED METHOD FOR FRAME STRUCTURE DWELLING |
UNI EN 15037-3 : 2011
|
PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 3: CLAY BLOCKS |
BS EN 13369:2013
|
Common rules for precast concrete products |
I.S. EN 13369:2013
|
COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
UNE-EN 16012:2013
|
Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance |
ISO 10456:2007
|
Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values |
I.S. EN ISO 10456:2007
|
BUILDING MATERIALS AND PRODUCTS - HYGROTHERMAL PROPERTIES - TABULATED DESIGN VALUES AND PROCEDURES FOR DETERMINING DECLARED AND DESIGN THERMAL VALUES |
BS ISO 19467:2017
|
Thermal performance of windows and doors. Determination of solar heat gain coefficient using solar simulator |
PD CEN/TR 14613:2003
|
Thermal performance of building materials and components. Principles for the determination of thermal properties of moist materials andcomponent s |
05/30134450 DC : DRAFT MAY 2005
|
ISO 10456 - BUILDING MATERIALS AND PRODUCTS - HYGROTHERMAL PROPERTIES - TABULATED DESIGN VALUES AND PROCEDURES FOR DETERMINING DECLARED AND DESIGN THERMAL VALUES |
09/30195952 DC : 0
|
BS ISO 12567-1 - THERMAL PERFORMANCE OF WINDOWS AND DOORS - DETERMINATION OF THERMAL TRANSMITTANCE BY HOT-BOX METHOD - PART 1: COMPLETE WINDOWS AND DOORS |
96/712499 DC : 0
|
PREN 12494 - BUILDING COMPONENTS AND ELEMENTS - IN SITU MEASUREMENT OF THE SURFACE-TO-SURFACE THERMAL RESISTANCE |
BS EN 15037-3 : 2009
|
PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 3: CLAY BLOCKS |
ASTM C 1199 : 2014 : REDLINE
|
Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods |
DIN EN 13369:2013-08
|
COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
ISO 12567-1:2010
|
Thermal performance of windows and doors Determination of thermal transmittance by the hot-box method Part 1: Complete windows and doors |
I.S. EN ISO 12567-1:2010
|
THERMAL PERFORMANCE OF WINDOWS AND DOORS - DETERMINATION OF THERMAL TRANSMITTANCE BY THE HOT-BOX METHOD - PART 1: COMPLETE WINDOWS AND DOORS |
ISO 18292:2011
|
Energy performance of fenestration systems for residential buildings Calculation procedure |
UNE-EN ISO 10456:2012
|
Building materials and products - Hygrothermal properties -Tabulated design values and procedures for determining declared and design thermal values (ISO 10456:2007) |
EN ISO 12567-1:2010/AC:2010
|
Thermal performance of windows and doors - Determination of thermal transmittance by the hot-box method - Part 1: Complete windows and doors - Technical Corrigendum 1 (ISO 12567-1:2010/Cor 1:2010) |
UNI EN ISO 12567-1 : 2010
|
THERMAL PERFORMANCE OF WINDOWS AND DOORS - DETERMINATION OF THERMAL TRANSMITTANCE BY THE HOT-BOX METHOD - PART 1: COMPLETE WINDOWS AND DOORS |
UNI EN ISO 10456 : 2008
|
BUILDING MATERIALS AND PRODUCTS - HYGROTHERMAL PROPERTIES - TABULATED DESIGN VALUES AND PROCEDURES FOR DETERMINING DECLARED AND DESIGN THERMAL VALUES |
PREN 13369 : DRAFT 2017
|
COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
07/30167926 DC : 0
|
BS ISO 9076-1 - THERMAL INSULATION - MINERAL-WOOL LOOSE-FILL FOR HORIZONTAL APPLICATIONS IN VENTILATED ROOF SPACES - PART 1: MATERIAL SPECIFICATION AND TEST METHODS |
16/30294393 DC : 0
|
BS ISO 19467 - THERMAL PERFORMANCE OF WINDOWS AND DOORS - DETERMINATION OF SOLAR HEAT GAIN COEFFICIENT USING SOLAR SIMULATOR |
UNE-EN 13369:2013
|
Common rules for precast concrete products |
EN 13369:2018
|
Common rules for precast concrete products |
I.S. EN 15037-3:2009
|
PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 3: CLAY BLOCKS |
BS EN ISO 12567-1:2010
|
Thermal performance of windows and doors. Determination of thermal transmittance by the hot-box method Complete windows and doors |
BS EN 1946-4:2000
|
Measurements by hot box methods |
BS EN ISO 12567-2:2005
|
Thermal performance of windows and doors. Determination of thermal transmittance by hot box method Roof windows and other projecting windows |
UNE-EN 15037-3:2010
|
Precast concrete products - Beam-and-block floor systems - Part 3: Clay blocks |
BS EN ISO 10456:2007
|
Building materials and products. Hygrothermal properties. Tabulated design values and procedures for determining declared and design thermal values |
EN ISO 12567-2:2005
|
Thermal performance of windows and doors - Determination of thermal transmittance by hot box method - Part 2: Roof windows and other projecting windows (ISO 12567-2:2005) |
EN 15037-3:2009+A1:2011
|
Precast concrete products - Beam-and-block floor systems - Part 3: Clay blocks |
EN 16012:2012+A1:2015
|
Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance |
18/30302605 DC : 0
|
BS ISO 16478 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - VACUUM INSULATION PANELS (VIP) - PRODUCTS SPECIFICATION |
BS ISO 18292:2011
|
Energy performance of fenestration systems for residential buildings. Calculation procedure |
BS EN 16012 : 2012
|
THERMAL INSULATION FOR BUILDINGS - REFLECTIVE INSULATION PRODUCTS - DETERMINATION OF THE DECLARED THERMAL PERFORMANCE |
UNI EN 13369 : 2013
|
COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
ASTM C 1363 : 2011 : REDLINE
|
Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
I.S. EN 13369:2018
|
COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
ISO/TR 15655:2003
|
Fire resistance Tests for thermo-physical and mechanical properties of structural materials at elevated temperatures for fire engineering design |
DIN EN ISO 12567-2:2006-03
|
Thermal performance of windows and doors - Determination of thermal transmittance by hot box method - Part 2: Roof windows and other projecting windows (ISO 12567-2:2005) |
BS EN 12412-4:2003
|
Thermal performance of windows, doors and shutters. Determination of thermal transmittance by hot box method Roller shutter boxes |
ISO 9869-1:2014
|
Thermal insulation Building elements In-situ measurement of thermal resistance and thermal transmittance Part 1: Heat flow meter method |
BS EN 12412-2:2003
|
Thermal performance of windows, doors and shutters. Determination of thermal transmittance by hot box method Frames |
ISO 12567-2:2005
|
Thermal performance of windows and doors Determination of thermal transmittance by hot box method Part 2: Roof windows and other projecting windows |
BS ISO 9869-1:2014
|
Thermal insulation. Building elements. 7IIn-situ7R measurement of thermal resistance and thermal transmittance Heat flow meter method |