EN ISO 8990:1996
Current
The latest, up-to-date edition.
Thermal insulation - Determination of steady-state thermal transmission properties - Calibrated and guarded hot box (ISO 8990:1994)
21-08-1996
Section 1 General
1.1 Scope
1.2 Normative reference
1.3 Definitions
1.4 Symbols, units and relationships
1.5 Principle
1.6 Limitations and sources of errors
Section 2 Apparatus
2.1 Introduction
2.2 Design requirements
2.3 Metering box
2.4 Guard box
2.5 Specimen frame
2.6 Cold side chamber
2.7 Temperature measurements
2.8 Instrumentation
2.9 Performance evaluation and calibration
Section 3 Test procedure
3.1 Introduction
3.2 Conditioning of specimen
3.3 Specimen selection and mounting
3.4 Test conditions
3.5 Measurement periods
3.6 Calculations
3.7 Test report
Annexes
A Heat transfer at surfaces and environmental temperatures
B Bibliography
Lays down the principles for the design of the apparatus and minimum requirement that shall be met for determination of the laboratory steady-state thermal transmission properties of building components and similar components for industrial use. Does not specify a particular design. Describes also the apparatus, measurement technique and necessary data reporting. Primarily intended for laboratory measurements of large, inhomogeneous specimens. Does not provide for measurements where there is mass transfer through the specimen during the test.
| Committee |
CEN/TC 89
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Current
|
| Standards | Relationship |
| ISO 8990:1994 | Identical |
| NBN EN ISO 8990 : 1996 | Identical |
| NEN EN ISO 8990 : 1997 | Identical |
| NS EN ISO 8990 : 1ED 1997 | Identical |
| I.S. EN ISO 8990:1997 | Identical |
| PN EN ISO 8990 : 1998 | Identical |
| SS-EN ISO 8990 :1996 | Identical |
| BS EN ISO 8990:1996 | Identical |
| NF EN ISO 8990 : 1996 | Identical |
| UNE-EN ISO 8990:1997 | Identical |