• EN ISO 9972:2015

    Current The latest, up-to-date edition.

    Thermal performance of buildings - Determination of air permeability of buildings - Fan pressurization method (ISO 9972:2015)

    Available format(s): 

    Language(s): 

    Published date:  09-09-2015

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms, definitions, and symbols
    4 Apparatus
    5 Measurement procedure
    6 Expression of results
    7 Test report
    8 Uncertainty
    Annex A (informative) - Description of equipment used
            to pressurize buildings
    Annex B (informative) - Dependence of air density on
            temperature, dew point, and barometric pressure
    Annex C (informative) - Recommended procedure for
            estimating uncertainty in derived quantities
    Annex D (informative) - Beaufort scale of wind (extract)
    Annex E (informative) - Detection of the leakage location

    Abstract - (Show below) - (Hide below)

    ISO 9972:2015 is intended for the measurement of the air permeability of buildings or parts of buildings in the field. It specifies the use of mechanical pressurization or depressurization of a building or part of a building. It describes the measurement of the resulting air flow rates over a range of indoor-outdoor static pressure differences.ISO 9972:2015 is intended for the measurement of the air leakage of building envelopes of single-zone buildings. For the purpose of this International Standard, many multi-zone buildings can be treated as single-zone buildings by opening interior doors or by inducing equal pressures in adjacent zones.ISO 9972:2015 does not address evaluation of air permeability of individual components.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 89
    Development Note Supersedes PREN ISO 9972 and EN 13829. (09/2015)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    DIN EN 12831-1:2017-09 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF THE DESIGN HEAT LOAD - PART 1: SPACE HEATING LOAD, MODULE M3-3
    I.S. EN 16750:2017 FIXED FIREFIGHTING SYSTEMS - OXYGEN REDUCTION SYSTEMS - DESIGN, INSTALLATION, PLANNING AND MAINTENANCE
    EN 12831-1:2017 Energy performance of buildings - Method for calculation of the design heat load - Part 1: Space heating load, Module M3-3
    BS EN 12831-1:2017 Energy performance of buildings. Method for calculation of the design heat load Space heating load, Module M3-3
    DIN EN 12831-1 E : 2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF THE DESIGN HEAT LOAD - PART 1: SPACE HEATING LOAD, MODULE M3-3
    PD CEN/TR 16798-4:2017 Energy performance of buildings. Ventilation for buildings Interpretation of the requirements in EN 16798-3. For non-residential buildings. Performance requirements for ventilation and room-conditioning systems(Modules M5-1, M5-4)
    BS EN 16750:2017 Fixed firefighting systems. Oxygen reduction systems. Design, installation, planning and maintenance
    BS EN 16883:2017 Conservation of cultural heritage. Guidelines for improving the energy performance of historic buildings
    I.S. EN 12831-1:2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF THE DESIGN HEAT LOAD - PART 1: SPACE HEATING LOAD, MODULE M3-3
    CEN/TR 16798-4:2017 Energy performance of buildings - Ventilation for buildings - Part 4: Interpretation of the requirements in EN 16798- 3 - For non-residential buildings - Performance requirements for ventilation and room-conditioning systems(Modules M5-1, M5-4)
    EN 16750:2017 Fixed firefighting systems - Oxygen reduction systems - Design, installation, planning and maintenance
    DIN EN 16750 E : 2017 FIXED FIREFIGHTING SYSTEMS - OXYGEN REDUCTION SYSTEMS - DESIGN, INSTALLATION, PLANNING AND MAINTENANCE
    DIN EN 16883 E : 2017 CONSERVATION OF CULTURAL HERITAGE - GUIDELINES FOR IMPROVING THE ENERGY PERFORMANCE OF HISTORIC BUILDINGS
    EN 16883:2017 Conservation of cultural heritage - Guidelines for improving the energy performance of historic buildings
    DIN EN 16750:2014-07 (Draft) FIXED FIREFIGHTING SYSTEMS - OXYGEN REDUCTION SYSTEMS - DESIGN, INSTALLATION, PLANNING AND MAINTENANCE
    17/30354084 DC : 0 BS EN 16855-2 - WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 2: CUSTOMIZED COLD ROOMS
    I.S. EN 16883:2017 CONSERVATION OF CULTURAL HERITAGE - GUIDELINES FOR IMPROVING THE ENERGY PERFORMANCE OF HISTORIC BUILDINGS
    DIN EN 16883:2015-07 (Draft) CONSERVATION OF CULTURAL HERITAGE - GUIDELINES FOR IMPROVING THE ENERGY PERFORMANCE OF HISTORIC BUILDINGS
    S.R. CEN/TR 16798-4:2017 ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 4: INTERPRETATION OF THE REQUIREMENTS IN EN 16798-3 - FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS (MODULES M5-1, M5-4)

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 7345:1987 Thermal insulation Physical quantities and definitions
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective