    FACILITIES CRITERIA - NAVY AND MARINE CORPS CHILD DEVELOPMENT CENTERS

    Available format(s): 

    Withdrawn date:  05-07-2023

    Language(s): 

    Published date:  30-09-2016

    Publisher:  US Military Specs/Standards/Handbooks

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    CHAPTER 1 - INTRODUCTION
    CHAPTER 2 - PLANNING AND LAYOUT
    CHAPTER 3 - GENERAL DESIGN CRITERIA
    CHAPTER 4 - SPECIFIC DESIGN CRITERIA
    CHAPTER 5 - OUTDOOR ACTIVITY AREAS
    APPENDIX A - REFERENCES
    APPENDIX B - BEST PRACTICES
    APPENDIX C - POISONOUS AND NON-POISONOUS PLANTS
    APPENDIX D - SAMPLE FURNISHINGS, FIXTURES AND EQUIPMENT LISTS
    APPENDIX E - SAMPLE KITCHEN EQUIPMENT
    APPENDIX F - GLOSSARY

    Abstract - (Show below) - (Hide below)

    Gives requirements for evaluating and planning the site, determining programming requirements, establishing space distribution needs, determining building size, and designing all outdoor and indoor spaces for Navy and Marine Corps Child Development Center (CDC) facilities to support the child development program.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher US Military Specs/Standards/Handbooks
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    UFC 3-600-01 : Change 2 UNIFIED FACILITIES CRITERIA - FIRE PROTECTION ENGINEERING FOR FACILITIES

    Standards Referencing This Book - (Show below) - (Hide below)

    ANSI Z97.1 : 2015 SAFETY GLAZING MATERIALS USED IN BUILDINGS - SAFETY PERFORMANCE SPECIFICATIONS AND METHODS OF TEST
    NFPA 96 : 2017 VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS
    NFPA 101 : 2018 LIFE SAFETY CODE
    CFR 16(PTS1000-END) : 0 COMMERCIAL PRACTICES - FEDERAL TRADE COMMISSION - CONSUMER PRODUCT SAFETY COMMISSION
    ASTM C 1396/C1396M : 2017 : REDLINE Standard Specification for Gypsum Board
    UFC 4-022-03 : 2013 UNIFIED FACILITIES CRITERIA - SECURITY FENCES AND GATES
    UFC 1-200-01 : 20071127 UNIFIED FACILITIES CRITERIA (UFC) DOD BUILDING CODE(GENERAL BUILDING REQUIREMENTS)
    ICC IBC INTERNATIONAL BUILDING CODE : 2015 INTERNATIONAL BUILDING CODE
    ASHRAE 62.1 : 2016 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
    CFR 29(PT1910.1000 TO END) : 0 LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
    UFC 3-410-01 : Change 4 UNIFIED FACILITIES CRITERIA - HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS
    NFPA 72 : 2016 NATIONAL FIRE ALARM AND SIGNALING CODE
    NFPA 13 : 2016 INSTALLATION OF SPRINKLER SYSTEMS
    ASTM F 1487 : 2017 : REDLINE Standard Consumer Safety Performance Specification for Playground Equipment for Public Use
    NFPA 720 : 2015 INSTALLATION OF CARBON MONOXIDE (CO) DETECTION AND WARNING EQUIPMENT
    UFC 4-021-01 : Change 1 UNIFIED FACILITIES CRITERIA - DESIGN AND O&M;: MASS NOTIFICATION SYSTEMS
    UFC 4-021-02 : 2013 UNIFIED FACILITIES CRITERIA - ELECTRONIC SECURITY SYSTEMS
    UFC 3-401-01 : Change 1 UNIFIED FACILITIES CRITERIA - MECHANICAL ENGINEERING
    UFC 3-530-01 : Change 3 UNIFIED FACILITIES CRITERIA - INTERIOR AND EXTERIOR LIGHTING SYSTEMS AND CONTROLS
    ASTM F 1951 : 2014 : REDLINE Standard Specification for Determination of Accessibility of Surface Systems Under and Around Playground Equipment
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective