• HD 621 S1:1996/A1:2001

    Current The latest, up-to-date edition.

    MV IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES OF RATED VOLTAGES OF 3.8/6.6 KV TO 19/33 KV

    Available format(s): 

    Language(s): 

    Published date:  05-07-2001

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    PART 1 General requirements
    PART 2 Additional test methods
    PART 3 Impregnated paper insulated cable-single core,
           also pre-assembled
           3-A Single core draining or non-draining paper
               insulated cable - unarmoured; with or without
               thermoplastic sheath (Type 3A)
           3-B Single core cables with paper insulation,
               non-draining
           3-C Impregnated paper insulated Gables - single
               core cables
           3-E Single core cables 12/20 kV and 18/30 kV
           3-F Single core cables, also pre-assembled
           3-G Cables with paper insulation - draining -
               unarmoured - PVC or PE sheathed - single core
           3-I Cables with PE sheath
           3-J-1 Single core and SL type paper insulated cables
                 with lead sheath (up to and including 12,7/22 kV)
           3-J-2 Single core and SL type paper insulated cables
                 with lead sheath (19/33 kV)
    PART 4 Impregnated paper insulated Gables - three core
           4-A Multicore draining or non-draining paper insulated
               cable - belted of screened cores - one or three
               metallic sheaths - armoured or unarmoured -
               thermoplastic sheath or not
           4-B Multicore cables with paper insulation, non
               draining
           4-C Impregnated paper insulated cable - belted H and
               SL type cables
           4-D Belted multicore cables with polypropylene yarn
               serving, or PVC or polyethylene sheath
           4-E Armoured three-core cables with lead sheaths
               12/20 kV and 18/30 kV and three-core cables
               12/15 kV non-radial field
           4-F Multicore Gables (Belted cables; three screened
               cores - one lead sheath; three metallic sheathed
               cores - one outer covering)
           4-G-1 Impregnated paper insulated cable - three core
                 draining paper insulated cable - screened cores,
                 one metallic sheath - airmoured or unarmoured
                 serving, PE or PVC sheath
           4-G-2 Impregnated paper insulated Gable - three core
                 draining paper insulated cable - belted, one
                 metallic sheath - armoured or unarmoured serving,
                 PE or PVC sheath
           4-H-1 Three-core belted and screened Gables, with lead
                 sheath and steel tape armour
           4-H-2 Three-core SL steel armoured cables
           4-I Cables with one lead sheath (Type 4I-1) and with
               three lead sheaths (Type 4I-2) and with sheaths of
               PE
           4-J-1 Three core cables with lead sheath (19/33 kV)
           4-J-2 Three core cables with lead sheath, up to and
                 including 12,7/22 kV
           4-J-3 Three core cables with aluminium sheath
           4-K Armoured three core Gables with lead sheaths
               and a rated voltage 23/40 kV

    Abstract - (Show below) - (Hide below)

    States the general requirements applicable to these cables, unless otherwise specified.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 20
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 7888-2:1998 LV and MV accessories for power cables with rated voltage from 0.6/1 kV (Um=1.2 kV) up to and including 20.8/36 kV (Um=42 kV) Methods of test
    BS EN 50363-9-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous insulating compounds. Cross-linked polyvinyl chloride (XLPVC)
    CEI 20-62/2 : 2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION
    CEI 20-62/1 : 2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION
    EN 50363-10-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC)
    EN 50363-9-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC)
    BS 7888-4.1(2006) : 2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION
    98/232755 DC : DRAFT DEC 1998 IEC 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
    03/315042 DC : DRAFT OCT 2003 CENELEC HD 629.1 S2 - TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION
    HD 629.1 S2:2006/A1:2008 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION
    VDE 0276-634 : 1999 TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV)
    DIN VDE 0276-633 : 1999 TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV)
    VDE 0276-635 : 1999 TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV)
    DIN VDE 0276-634 : 1999 TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV)
    DIN VDE 0276-635 : 1999 TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV)
    VDE 0276-633 : 1999 TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV)
    I.S. HD 629.1:2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3.6/6(7.2) KV UP TO 20.8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION
    03/315043 DC : DRAFT OCT 2003 CENELEC HD 629.2 S2 - TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION
    BS EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables General introduction
    BS EN 50363-10-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Cross-linked polyvinyl chloride (XLPVC)
    I.S. EN 50363-9-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 9-1: MISCELLANEOUS INSULATING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC)
    I.S. EN 50363-0:2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW-VOLTAGE ENERGY CABLES - PART 0: GENERAL INTRODUCTION
    I.S. HD 629-2:2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION
    UNE-EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables -- Part 0: General introduction
    HD 629.2 S2:2006/A1:2008 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION
    BS 7888-4.2(2006) : 2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION
    EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective