WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS
Hardcopy , PDF
12-04-2010
English
10-05-2006
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Performance characteristics and special requirements
5 Classification and designation
6 Handling, installation, maintenance and care
7 Evaluation of conformity
8 Labelling and marking
Annex A (informative) - Interdependence between
characteristics and components
Annex B (normative) - Determination of sound insulation of windows
Annex C (informative) - Standards and draft standards on glass
Annex D (informative) - Examples of performance and
requirement profiles of a roof window
Annex E (normative) - Determination of characteristics
Annex F (informative) - Optional selection of representative
test specimens for windows
Annex G (informative) - Examples of test sequences
for optional combined determination of characteristics
for windows
Annex H (normative) - Selection, preparation, mounting
and fixing of test specimen for testing roof windows in
accordance with EN 13823 and EN ISO 11925-2 and field of
direct application
Annex I (normative) - Classification of air permeability
of products with described product characteristics
Annex J (normative) - Thermal transmittance for windows with bars
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Product Directive
Annex ZB (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 98/37/EC
Annex ZC (informative) - Relationship between this European
Standard and the Essential Requirements of
EU Directive 2006/95/EC
Annex ZD (informative) - Relationship between this
European Standard and the Essential Requirements
of EU Directive 2006/42/EC
Bibliography
Describes material independent performance characteristics, except resistance to fire and smoke control characteristics, that are applicable to windows (including roof windows, roof windows with external fire resistance and door height windows), external pedestrian doorsets (and their assemblies, including unframed glass doorsets, escape route doorsets) and screens.
DevelopmentNote |
2006 Edition Re-issued in October 2016 & incorporates AMD 2 2016. (10/2016)
|
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
NS EN 14351-1 : 2006 + A2 + NA 17 | Identical |
UNE-EN 14351-1:2006 | Identical |
NF EN 14351-1 : 2006 + A2 2016 | Identical |
DIN EN 14351-1:2010-08 | Identical |
BS EN 14351-1 : 2006 | Identical |
UNI EN 14351-1 : 2010 | Identical |
SN EN 14351-1 : 2006 + A2 2016 | Identical |
EN 14351-1:2006+A2:2016 | Identical |
NEN EN 14351-1 : 2006 + A2 2016 | Identical |
NBN EN 14351-1 : 2006 + A2 2016 | Identical |
DIN EN 14351-1:2006-07 | Identical |
S.R. 82:2017 | SLATING AND TILING - CODE OF PRACTICE |
ENV 1630:1999 | Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts |
EN 14321-2:2005 | Glass in building - Thermally toughened alkaline earth silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 12210:2016 | Windows and doors - Resistance to wind load - Classification |
EN 950:1999 | Door leaves - Determination of the resistance to hard body impact |
EN 60335-2-103:2015 | Household and similar electrical appliances - Safety - Part 2-103: Particular requirements for drives for gates, doors and windows |
EN 16361:2013+A1:2016 | Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 13124-2:2004 | Windows, doors and shutters - Explosion resistance - Test method - Part 2: Range test |
EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 1096-4:2004 | Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
EN 14609:2004 | Windows - Determination of the resistance to static torsion |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
EN 1026:2016 | Windows and doors - Air permeability - Test method |
EN 13123-2:2004 | Windows, doors, and shutters - Explosion resistance - Requirements and classification - Part 2: Range test |
ENV 13420:2000 | Windows - Behaviour between different climates - Test method |
EN 1523:1998 | Windows, doors, shutters and blinds - Bullet resistance - Test method |
ENV 1629:1999 | Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading |
EN 1027:2016 | Windows and doors - Water tightness - Test method |
EN ISO 12543-2:2011 | Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011) |
EN 12400:2002 | Windows and pedestrian doors - Mechanical durability - Requirements and classification |
EN 14608:2004 | Windows - Determination of the resistance to racking |
EN 13241:2003+A2:2016 | Industrial, commercial, garage doors and gates - Product standard, performance characteristics |
ISO 11925-2:2010 | Reaction to fire tests Ignitability of products subjected to direct impingement of flame Part 2: Single-flame source test |
EN 13501-5:2016 | Fire classification of construction products and building elements - Part 5: Classification using data from external fire exposure to roofs tests |
ISO 140-3:1995 | Acoustics — Measurement of sound insulation in buildings and of building elements — Part 3: Laboratory measurements of airborne sound insulation of building elements |
EN 13115:2001 | Windows - Classification of mechanical properties - Racking, torsion and operating forces |
EN 1748-1-2:2004 | Glass in building - Special basic products - Borosilicate glasses - Part 1-2: Evaluation of conformity/Product standard |
ISO 10077-2:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames |
EN 12207:2016 | Windows and doors - Air permeability - Classification |
EN 12211:2016 | Windows and doors - Resistance to wind load - Test method |
EN 12208:1999 | Windows and doors - Watertightness - Classification |
EN 14179-2:2005 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 13238:2010 | Reaction to fire tests for building products - Conditioning procedures and general rules for selection of substrates |
ISO 12543-2:2011 | Glass in building Laminated glass and laminated safety glass Part 2: Laminated safety glass |
EN 948:1999 | Hinged or pivoted doors - Determination of the resistance to static torsion |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN 12519:2004 | Windows and pedestrian doors - Terminology |
EN ISO 10077-2:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2017) |
EN 1192:1999 | Doors - Classification of strength requirements |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
EN 1121:2000 | Doors - Behaviour between two different climates - Test method |
EN 13123-1:2001 | Windows, doors and shutters - Explosion resistance - Requirements and classification - Part 1: Shock tube |
ISO 12567-1:2010 | Thermal performance of windows and doors Determination of thermal transmittance by the hot-box method Part 1: Complete windows and doors |
EN 572-9:2004 | Glass in building - Basic soda lime silicate glass products - Part 9: Evaluation of conformity/Product standard |
EN 1863-2:2004 | Glass in building - Heat strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard |
EN 12046-2:2000 | Operating forces - Test method - Part 2: Doors |
EN 12337-2:2004 | Glass in building - Chemically strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard |
EN 947:1998 | Hinged or pivoted doors - Determination of the resistance to vertical load |
PREN 13637 : DRAFT 2014 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 12567-2:2005 | Thermal performance of windows and doors — Determination of thermal transmittance by hot box method — Part 2: Roof windows and other projecting windows |
EN 13141-1:2004 | Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 1: Externally and internally mounted air transfer devices |
EN 12150-2:2004 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 14178-2:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 2: Evaluation of conformity/Product standard |
EN 13124-1:2001 | Windows, doors and shutters - Explosion resistance - Test method - Part 1: Shock tube |
EN 1279-5:2005+A2:2010 | Glass in building - Insulating glass units - Part 5: Evaluation of conformity |
EN 13830:2015 | Curtain walling - Product standard |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
EN 1748-2-2:2004 | Glass in building - Special basic products - Part 2-2: Glass ceramics - Evaluation of conformity/Product standard |
EN 13049:2003 | Windows - Soft and heavy body impact - Test method, safety requirements and classification |
EN 12354-3:2000 | Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 3: Airborne sound insulation against outdoor sound |
EN 12217:2015 | Doors - Operating forces - Requirements and classification |
ISO 9001:2015 | Quality management systems — Requirements |
ENV 1628:1999 | Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance under static loading |
EN 12219:1999 | Doors - Climatic influences - Requirements and classification |
EN 12608:2003 | Unplasticized polyvinylchloride (PVC-U) profiles for the fabrication of windows and doors - Classification, requirements and test methods |
ENV 1627:1999 | Windows, doors, shutters - Burglar resistance - Requirements and classification |
ISO 717-1:2013 | Acoustics Rating of sound insulation in buildings and of building elements Part 1: Airborne sound insulation |
EN 1522:1998 | Windows, doors, shutters and blinds - Bullet resistance - Requirements and classification |
EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
EN 949:1998 | Windows and curtain walling, doors, blinds and shutters - Determination of the resistance to soft and heavy body impact for doors |
EN 13024-2:2004 | Glass in building - Thermally toughened borosilicate safety glass - Part 2: Evaluation of conformity/Product standard |
PREN 14351-2 : DRAFT 2014 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
EN 12046-1:2003 | Operating forces - Test method - Part 1: Windows |
ISO 10077-1:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General |
EN 1873:2014+A1:2016 | Prefabricated accessories for roofing - Individual rooflights of plastics - Product specification and test methods |
EN 1191:2012 | Windows and doors - Resistance to repeated opening and closing - Test method |
EN ISO 12567-2:2005 | Thermal performance of windows and doors - Determination of thermal transmittance by hot box method - Part 2: Roof windows and other projecting windows (ISO 12567-2:2005) |
EN 14963:2006 | Roof coverings - Continuous rooflights of plastics with or without upstands - Classification, requirements and test methods |
EN ISO 10077-1:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02) |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
EN 179:2008 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |
IEC 60335-2-103:2015+AMD1:2017 CSV | Household and similar electrical appliances - Safety - Part 2-103: Particular requirements for drives for gates, doors and windows |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.