• Shopping Cart
    There are no items in your cart

I.S. EN 14944-3:2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

INFLUENCE OF CEMENTITIOUS PRODUCTS ON WATER INTENDED FOR HUMAN CONSUMPTION - TEST METHODS - PART 3: MIGRATION OF SUBSTANCES FROM FACTORY-MADE CEMENTITITOUS PRODUCTS

Available format(s)

Hardcopy , PDF

Superseded date

11-01-2024

Superseded by

I.S. EN 14944-3:2023

Language(s)

English

Published date

01-01-2007

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

€88.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and Definitions
4 Principle
5 Reagents
   5.1 General requirements
   5.2 Disinfection reagents
        5.2.1 Sodium hypochlorite solution
        5.2.2 Disinfection treatment water
   5.3 Waters to be used for testing
        5.3.1 Preconditioning water
        5.3.2 Test water
        5.3.3 Test water without chlorine content (chlorine-free)
        5.3.4 Test water with chlorine content (chlorinated)
   5.4 Cleaning liquids for apparatus
6 Apparatus
   6.1 General
   6.2 Apparatus and materials for test piece preparation
        6.2.1 Stainless steel plates and cylinders
        6.2.2 Glass cylinders
        6.2.3 Moulds for forming test pieces
   6.3 Apparatus and materials for preconditioning and
        migration procedure
        6.3.1 Vessels, containers, covers, connectors and stoppers
7 Samples and test pieces
   7.1 Sampling, transport and storage of samples
   7.2 Preparation of test pieces
        7.2.1 General
        7.2.2 Factory made pipes, fittings and storage systems
   7.3 Surface area-to-volume ratio (S/V) for use in the
        test procedure
        7.3.1 General
        7.3.2 Pipes and fittings
        7.3.3 Storage systems (cement mortar, cement
              mortar lined or concrete)
8 Pre-treatment of samples (curing, preconditioning and
   disinfection)
   8.1 General
   8.2 Curing
   8.3 Preconditioning
        8.3.1 General
        8.3.2 Preconditioning without disinfection treatment
        8.3.3 Preconditioning with disinfection treatment
9 Test procedure
   9.1 General
   9.2 Preparation of migration water for analysis of substances
        9.2.2 Second and third migration periods
        9.2.3 Additional migration periods
   9.3 Control samples (blank test)
10 Analysis
11 Calculation of test results
   11.1 Calculation of the concentration of the
        substances in the migration water
   11.2 Calculation of the migration rate of the measured
        substances
   11.3 Calculation of the mean migration rate
12 Test report
   12.1 General information
   12.2 Information on the product
   12.3 Information on the test procedure
   12.4 Test results
Annex A (normative) - Additional procedures for testing
                      factory made pipes (cement mortar
                      lined and concrete)
         A.1 Sampling, test piece preparation and storage
             A.1.1 Sampling
             A.1.2 Test piece preparation and storage
         A.2 Surface area to volume (S/V) ratio
         A.3 Pretreatment of test pieces
             (preconditioning and disinfection)
         A.4 Test procedure
             A.4.1 Migration procedure at 23 degree C
             A.4.2 Migration procedure at elevated temperature
         A.5 Expression of results
         A.6 Reporting
Annex B (normative) - Additional procedures for testing
                      factory made fittings (cement mortar
                      lined and concrete)
         B.1 Sampling, test piece preparation and storage
             B.1.1 Sampling of Factory made fittings
             B.1.2 Test piece preparation and storage
         B.2 Surface area to volume (S/V) ratio
         B.3 Pre-treatment of test pieces
             (preconditioning and disinfection)
         B.4 Test procedure
             B.4.1 Migration procedure at 23 degree C
             B.4.2 Migration procedure at elevated temperature
         B.5 Expression of results
         B.6 Reporting
Annex C (normative) - Additional procedures for testing
                      factory made storage systems (cement
                      mortar, cement mortar lined and concrete)
         C.1 Sampling, test piece preparation and storage
             C.1.1 Sampling
             C.1.2 Test piece preparation and storage
         C.2 Surface area to volume (S/V) ratio
         C.3 Pretreatment of test pieces
             (preconditioning and disinfection)
         C.4 Test procedure
             C.4.1 Migration procedure at 23 degree C
             C.4.2 Migration procedure at elevated temperature
         C.5 Expression of results
         C.6 Reporting
Annex D (informative) - Examples of typical test pieces
                        and test conditions as a function
                        of S/V ratio
         D.1 General
         D.2 Pipes and fittings
         D.3 Test pieces to which a cylinder of stainless
             steel or glass is to be attached
         D.4 Square test plates coated with mortar
         D.5 Moulded test pieces where all faces
             are exposed to test water
Annex E (informative) - Test arrangements for testing
                        factory made cementitious products
Annex F (normative) - Additional procedures for testing
                      factory made cementitious products
                      at elevated temperature
         F.1 General
         F.2 Test procedure at elevated temperature
             F.2.1 General
             F.2.2 Preparation of migration water for the
                   assessment of migration of substances
         F.3 Control samples (blank test)
         F.4 Expression of results
         F.5 Reporting
Annex G (informative) - Discrimination between porous
                        and non-porous coatings on factory
                        made products
         G.1 Principle
         G.2 Apparatus
             G.2.1 stainless steel plates
             G.2.2 cylinders
             G.2.3 pH meter
         G.3 Materials and reagents
             G.3.1 sealing compound/sealant
             G.3.2 demineralized water
         G.4 Test procedure
             G.4.1 General
             G.4.2 Laboratory blank
             G.4.3 Coated product
         G.5 Determination of pH
         G.6 Expression of results
         G.7 Classification criteria
Annex H (informative) - Schematic description of the
                        test procedure
         H.1 Preconditioning
         H.2 Production of migration water at 23 degree C
         H.3 Typical Schedule
             H.3.1 Preconditioning
             H.3.2 Production of migration waters
Annex I (informative) - Procedural tests using standard
                        additions (positive controls)
Bibliography

Describes a method to determine the migration of substances from factory made cementitious products into test waters after contact with the products.

DocumentType
Standard
Pages
55
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

EN ISO 7393-1:2000 Water quality - Determination of free chlorine and total chlorine - Part 1: Titrimetric method using N, N-diethyl-1,4-phenylenediamine (ISO 7393-1:1985)
ISO 16132:2016 Ductile iron pipes and fittings — Seal coats for cement mortar linings
ISO/TR 13530:1997 Water quality Guide to analytical quality control for water analysis
EN 1015-11 : 1999 AMD 1 2006 METHODS OF TEST FOR MORTAR FOR MASONRY - PART 11: DETERMINATION OF FLEXURAL AND COMPRESSIVE STRENGTH OF HARDENED MORTAR
EN 196-1:2016 Methods of testing cement - Part 1: Determination of strength
ENV ISO 13530:1998 Water quality - Guide to analytical quality control for water analysis (ISO/TR 13530:1997)
EN 12390-1:2012 Testing hardened concrete - Part 1: Shape, dimensions and other requirements for specimens and moulds
EN 12390-2:2009 Testing hardened concrete - Part 2: Making and curing specimens for strength tests
ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
EN 12350-1:2009 Testing fresh concrete - Part 1: Sampling
EN ISO 3696:1995 Water for analytical laboratory use - Specification and test methods (ISO 3696:1987)
ISO 7393-2:1985 Water quality Determination of free chlorine and total chlorine Part 2: Colorimetric method using N,N-diethyl-1,4-phenylenediamine, for routine control purposes
ISO 10523:2008 Water quality — Determination of pH
EN 10088-1:2014 Stainless steels - Part 1: List of stainless steels

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.