I.S. EN 16450:2017
Current
The latest, up-to-date edition.
AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
Hardcopy , PDF
English
01-01-2017
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Principle
6 Sampling
7 Type testing
8 Field operation and ongoing quality control
9 Data handling, validation and data reports
10 Reporting of AMS data
11 Test reports and documentation - Field operation
Annex A (informative) - Examples of principles of AMS
for monitoring particulate matter
Annex B (normative) - Orthogonal regression algorithms
Annex C (normative) - Performing calibrations of the AMS
Annex D (normative)- Elements of type testing report
Annex E (informative) - Elements of suitability evaluation
report
Bibliography
Defines the minimum performance requirements and test procedures for the type approval of appropriate AMS for particulate matter.
DevelopmentNote |
Supersedes SR CEN/TS 16450. (05/2017)
|
DocumentType |
Standard
|
Pages |
56
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 16450:2017 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
EN 15267-2:2009 | Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process |
EN 14211:2012 | Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence |
ISO 21501-4:2007 | Determination of particle size distribution Single particle light interaction methods Part 4: Light scattering airborne particle counter for clean spaces |
EN 15267-1:2009 | Air quality - Certification of automated measuring systems - Part 1: General principles |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 12341:2014 | Ambient air - Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.