• I.S. EN 29104:1994

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    MEASUREMENT OF FLUID FLOW IN CLOSED CONDUITS - METHODS OF EVALUATING THE PERFORMANCE OF ELECTROMAGNETIC FLOW-METERS FOR LIQUIDS

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  30-04-2020

    Language(s):  English

    Published date:  01-01-1994

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    National foreword
    Methods
    Introduction
    1 Scope
    2 Normative references
    3 Definitions
    4 General testing procedure
    5 Evaluation of the effect of an influence quantity
    6 Tests for the evaluation of the effects of other
        influence quantities
    Figures
    1 Sample calibration showing distribution of test
        points
    2 Typical circuit arrangements for upstream gate valve
        tests
    3 Examples showing the effects of an upstream gate
        valve on three electromagnetic meters of DN 500
        (based on real data)
    4 Annular or segmental obstructions used to determine
        the effects of a disturbance in the inlet flow on
        the response of the flow-meter
    5 General test circuit
    6 Test of the effect of a) mains frequency common-mode
        voltage (voltage applied between the earth of the
        primary and secondary devices) and b) mains
        frequency voltage between neutral and primary earth
        (voltage applied between earth and mains, if
        practicable)
    7 Test of the effect of mains frequency voltage
        between earth and output terminals
    8 Test of the effect of a.c. currents on earthed
        connection between primary and secondary devices
    9 Test of the effect of series-mode signals at the
        supply frequency
    10 Test of the effect of stray currents within the
        liquid
    Annex
    A Bibliography

    Abstract - (Show below) - (Hide below)

    Recommends methods of test for the evaluation of the performance of electromagnetic flow-meters for liquids flowing in closed conduits.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Withdrawn