• NF EN 29104 : 1993

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    MEASUREMENT OF FLUID FLOW IN CLOSED CONDUITS - METHODS OF EVALUATING THE PERFORMANCE OF ELECTROMAGNETIC FLOW-METERS FOR LIQUIDS

    Available format(s): 

    Superseded date:  29-09-2021

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Association Francaise de Normalisation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    National foreword
    Methods
    Introduction
    1 Scope
    2 Normative references
    3 Definitions
    4 General testing procedure
    5 Evaluation of the effect of an influence quantity
    6 Tests for the evaluation of the effects of other
        influence quantities
    Figures
    1 Sample calibration showing distribution of test
        points
    2 Typical circuit arrangements for upstream gate valve
        tests
    3 Examples showing the effects of an upstream gate
        valve on three electromagnetic meters of DN 500
        (based on real data)
    4 Annular or segmental obstructions used to determine
        the effects of a disturbance in the inlet flow on
        the response of the flow-meter
    5 General test circuit
    6 Test of the effect of a) mains frequency common-mode
        voltage (voltage applied between the earth of the
        primary and secondary devices) and b) mains
        frequency voltage between neutral and primary earth
        (voltage applied between earth and mains, if
        practicable)
    7 Test of the effect of mains frequency voltage
        between earth and output terminals
    8 Test of the effect of a.c. currents on earthed
        connection between primary and secondary devices
    9 Test of the effect of series-mode signals at the
        supply frequency
    10 Test of the effect of stray currents within the
        liquid
    Annex
    A Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the evaluation of the performance of electromagnetic flow-meters for liquids flowing in closed conduits. It specifies a uniform procedure to verify the performance characteristics when the flow-meter is subjected to identified influence quantities and methods of representing the results of performance measurements.

    General Product Information - (Show below) - (Hide below)

    Development Note Indice de classement: X10-121. (05/2015)
    Document Type Standard
    Publisher Association Francaise de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    NFM 60 825 : 2012 ENERGIE NUCLEAIRE - MESURE DE LA RADIOACTIVITE DANS LES EFFLUENTS GAZEUX ET LIQUIDES - ECHANTILLONNAGE DES EFFLUENTS LIQUIDES DANS UN RECIPIENT OU UN EMISSAIRE DE REJET
    FD T90 523-2 : 2008 FD WATER QUALITY - SAMPLING GUIDE FOR MONITORING QUALITY OF WATERS IN THE ENVIRONMENT - PART 2: SAMPLING OF WASTEWATER
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective