I.S. EN 45502-1:2015
Current
The latest, up-to-date edition.
IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND FOR INFORMATION TO BE PROVIDED BY THE MANUFACTURER
Hardcopy , PDF
English
01-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations (optional)
5 General requirements for ACTIVE IMPLANTABLE
MEDICAL DEVICES
6 Requirements for particular ACTIVE IMPLANTABLE
MEDICAL DEVICES
7 General arrangement of the packaging
8 General MARKINGS for ACTIVE IMPLANTABLE
MEDICAL DEVICES
9 MARKINGS on the SALES PACKAGING
10 Construction of the SALES PACKAGING
11 MARKINGS on the STERILE PACK
12 Construction of the NON-REUSABLE PACK
13 MARKINGS on the ACTIVE IMPLANTABLE MEDICAL
DEVICE
14 Protection from unintentional biological effects being
caused by the ACTIVE IMPLANTABLE MEDICAL DEVICE
15 Protection from HARM to the patient or user caused by
external physical features of the ACTIVE IMPLANTABLE
MEDICAL DEVICE
16 Protection from HARM to the patient caused by electricity
17 Protection from HARM to the patient caused by heat
18 Protection from ionizing radiation released or emitted
from the ACTIVE IMPLANTABLE MEDICAL DEVICE
19 Protection from unintended effects caused by the
ACTIVE IMPLANTABLE MEDICAL DEVICE
20 Protection of the ACTIVE IMPLANTABLE MEDICAL
DEVICE from damage caused by external defibrillators
21 Protection of the ACTIVE IMPLANTABLE MEDICAL
DEVICE from changes caused by electrical fields applied
directly to the patient
22 Protection of the ACTIVE IMPLANTABLE MEDICAL
DEVICE from changes caused by miscellaneous medical
treatments
23 Protection of the ACTIVE IMPLANTABLE MEDICAL
DEVICE from mechanical forces
24 Protection of the ACTIVE IMPLANTABLE MEDICAL
DEVICE from damage caused by electrostatic discharge
25 Protection of the ACTIVE IMPLANTABLE MEDICAL
DEVICE from damage caused by atmospheric pressure
changes
26 Protection of the ACTIVE IMPLANTABLE MEDICAL
DEVICE from damage caused by temperature changes
27 Protection of the ACTIVE IMPLANTABLE MEDICAL
DEVICE from electromagnetic non-ionizing radiation
28 Accompanying documentation
Annex A (informative) - General guidance and rationale
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZZ (informative) - Relationship between this
European Standard and the Essential
Requirements of EU Directive 90/385/EEC on
Active Implantable Medical Devices
Bibliography
Provides requirements that are generally applicable to ACTIVE IMPLANTABLE MEDICAL DEVICES.
DocumentType |
Standard
|
Pages |
64
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 45502-1 : 2015 | Identical |
NBN EN 45502-1 : 2015 | Identical |
NF EN 45502-1 : 1998 | Identical |
NS EN 45502-1 : 1997 | Identical |
NEN EN 45502-1 : 2015 | Identical |
BS EN 45502-1:2015 | Identical |
SN EN 45502-1 : 1997 | Identical |
DIN EN 45502-1 : 2016 | Identical |
UNE-EN 45502-1:1998 | Identical |
EN 45502-1:2015 | Identical |
IEC 62127-1:2007+AMD1:2013 CSV | Ultrasonics - Hydrophones - Part 1: Measurement and characterizationof medical ultrasonic fields up to 40 MHz |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
EN ISO 14937:2009 | Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices (ISO 14937:2009) |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
EN 60068-2-64:2008 | ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
EN 50061 : 88 AMD 1 95 | SAFETY OF IMPLANTABLE CARDIAC PACEMAKERS |
EN ISO 10993-9:2009 | Biological evaluation of medical devices - Part 9: Framework for identification and quantification of potential degradation products (ISO 10993-9:2009) |
EN 62304:2006/A1:2015 | MEDICAL DEVICE SOFTWARE - SOFTWARE LIFE-CYCLE PROCESSES (IEC 62304:2006/A1:2015) |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
IEC 62366:2007+AMD1:2014 CSV | Medical devices - Application of usability engineering to medical devices |
ISO 11135-1:2007 | Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO/TR 14283:2004 | Implants for surgery Fundamental principles |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 62304:2006+AMD1:2015 CSV | Medical device software - Software life cycle processes |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
EN ISO 11137-2:2015 | Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose (ISO 11137-2:2013) |
ISO 8601:2004 | Data elements and interchange formats Information interchange Representation of dates and times |
EN ISO 11135-1:2007 | Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 11135-1:2007) |
ISO 11137-2:2013 | Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
EN 62366 : 2008 AMD 1 2015 | MEDICAL DEVICES - APPLICATION OF USABILITY ENGINEERING TO MEDICAL DEVICES (IEC 62366:2007/A1:2014) |
EN ISO 11137-1:2015 | Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 11137-1:2006, including Amd 1:2013) |
EN ISO 14971:2012 | Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01) |
ISO 10993-9:2009 | Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products |
ISO/TS 10974:2012 | Assessment of the safety of magnetic resonance imaging for patients with an active implantable medical device |
ISO 14155:2011 | Clinical investigation of medical devices for human subjects Good clinical practice |
EN ISO 17665-1:2006 | Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 17665-1:2006) |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
ISO 15223-1:2016 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements |
AAMI TIR42 : 2010 | EVALUATION OF PARTICULATES ASSOCIATED WITH VASCULAR MEDICAL DEVICES |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 62127-1:2007/A1:2013 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007/A1:2013) |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.