1 Scope
2 Normative references
3 Definitions
4 Categories of intrinsically safe electrical systems
(in accordance with EN 50014)
5 Interconnecting wiring/cables used in an intrinsically
safe electrical system
6 Accessories for intrinsically safe electrical systems
7 Type tests and assessment
8 Marking of intrinsically safe electrical systems
9 Descriptive system document
10 Instructions
Annex A (normative) - Requirements for cables
Annex B (informative) - Typical descriptive system drawing
Annex C (normative) - Assessment of a simple intrinsically
safe system
Annex D (normative) - Assessment of circuits with more than
one linear source of power
Annex E (normative) - Trapezoidal power supplies
Annex F (normative) - Non-linear power supplies
Annex G (normative) - Verification of inductive parameters
Contains the requirements for construction and testing of Group I intrinsically safe electrical systems intended for use, as a whole or in part, in atmospheres susceptible to firedamp.
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 50394-1 : 2004 | Identical |
BS EN 50394-1:2004 | Identical |
UNE-EN 50394-1:2005 | Identical |
EN 50394-1:2004 | Identical |
NEN EN 50394-1 : 2004 | Identical |
NBN EN 50394-1 : 2005 | Identical |
DIN EN 50394-1 : 2004 | Identical |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
EN 50014:1997/A2:1999 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
EN 50303:2000 | Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust |