• There are no items in your cart

I.S. EN 50527-2-1:2016

Current

Current

The latest, up-to-date edition.

PROCEDURE FOR THE ASSESSMENT OF THE EXPOSURE TO ELECTROMAGNETIC FIELDS OF WORKERS BEARING ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-1: SPECIFIC ASSESSMENT FOR WORKERS WITH CARDIAC PACEMAKERS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2016

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

€99.00
Excluding VAT

National Foreword
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Specific assessment
5 Documentation
Annex A (normative) - Pacemaker specific replacement of
        50527-1:2016, Table 1
Annex B (informative) - Clinical investigation methods
Annex C (informative) - in vitro testing/measurements
Annex D (informative) - Modelling
Annex E (informative) - Derived worst case conversions
        for frequencies below 450 MHz
Annex F (informative) - Interference from power-frequency
        magnetic and electric fields from transmission,
        distribution and use of electricity
Annex G (informative) - Determination of the pacemaker
        immunity and guidelines provided by
        pacemaker manufacturers - Determination method
Bibliography

Defines the procedure for the specific assessment required in EN 50527-1:2016, Annex A, for workers with implanted pacemakers.

DocumentType
Standard
Pages
76
PublisherName
National Standards Authority of Ireland
Status
Current

Standards Relationship
EN 50527-2-1:2016 Identical

AAMI PC69 : 2007
IEC 62209-2:2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)
EN 62226-3-1:2007/A1:2017 EXPOSURE TO ELECTRIC OR MAGNETIC FIELDS IN THE LOW AND INTERMEDIATE FREQUENCY RANGE - METHODS FOR CALCULATING THE CURRENT DENSITY AND INTERNAL ELECTRIC FIELD INDUCED IN THE HUMAN BODY - PART 3-1: EXPOSURE TO ELECTRIC FIELDS - ANALYTICAL AND 2D NUMERICAL MODELS (IEC 62226-3-1:2007/A1:2016)
ISO 14117:2012 Active implantable medical devices Electromagnetic compatibility EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices
IEEE 1528-2013 REDLINE IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques
EN 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
EN 50527-1:2016 Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 1: General
ISO 14155:2011 Clinical investigation of medical devices for human subjects Good clinical practice
EN 50413 : 2008 AMD 1 2013 BASIC STANDARD ON MEASUREMENT AND CALCULATION PROCEDURES FOR HUMAN EXPOSURE TO ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)
EN 50499:2008 Procedure for the assessment of the exposure of workers to electromagnetic fields

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.