I.S. EN 54-12:2015
Current
The latest, up-to-date edition.
FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM
Hardcopy , PDF
English
01-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of
performance (AVCP)
7 Classification and designation
8 Marking, labelling and packaging
Annex A (normative) - Bench for response value measurements
Annex B (normative) - Fire test room
Annex C (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex D (normative) - Glowing smouldering cotton fire (TF3)
Annex E (normative) - Flaming plastics (polyurethane) fire (TF4)
Annex F (normative) - Flaming liquid (n-heptane) fire (TF5)
Annex G (normative) - Apparatus for stray light
Annex H (informative) - Information concerning the
requirements for the response to slowly developing
fires
Annex I (informative) - Data supplied with line detectors
using an optical beam
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Regulation
Bibliography
Defines requirements, test methods and performance criteria for line detectors using an optical beam that detect smoke by utilizing the attenuation and/or changes in attenuation of an optical beam, for use in fire detection and fire alarm systems installed in buildings.
DocumentType |
Standard
|
Pages |
74
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
SN EN 54-12:2015 | Identical |
NBN EN 54-12 : 2015 | Identical |
ONORM EN 54-12 : 2015 | Identical |
NF EN 54-12 : 2015 | Identical |
EN 54-12:2015 | Identical |
UNI EN 54-12 : 2003 | Identical |
BS EN 54-12:2015 | Identical |
DIN EN 54-12:2015-10 | Identical |
NEN EN 54-12 : 2015 | Identical |
NS EN 54-12 : 2002 | Identical |
UNE-EN 54-12:2003 | Identical |
I.S. 3218:2013 | FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - SYSTEM DESIGN, INSTALLATION, COMMISSIONING, SERVICING AND MAINTENANCE |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV | Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements |
EN 60064:1995/A5:2009 | TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |