Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Product characteristics
5 Testing, assessments and sampling methods
6 Assessment and verification of constancy of
performance (AVCP)
7 Classification
8 Marking, labelling and packaging
Annex A (normative) - Arrangement of the sensing
element in the fire test room
Annex B (normative) - Flaming liquid test fires
(TF6F, TF6 and TF6S)
Annex C (normative) - Test arrangement for the
sensing element of linear heat detector in
the heat tunnel
Annex D (informative) - Apparatus for mounting of the
sensing element of linear heat detector in the
heat tunnel
Annex E (normative) - Mounting of the sensing element
of multipoint RLTHD in the heat tunnel
Annex F (normative) - Heat tunnel for response time and
of multipoint RLTHD in the heat tunnel
Annex F (normative) - Heat tunnel for response time and
response temperature measurements
Annex G (informative) - Construction of the heat
tunnel
Annex H (normative) - Test arrangement for vibration tests
for sensing element
Annex I (normative) - Test apparatus for impact test on the
sensing element
Annex J (informative) - Data supplied with resettable
line-type heat detectors
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Regulation
Bibliography
Pertains to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works.
| DocumentType |
Standard
|
| Pages |
86
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| EN 54-22:2015 | Identical |
| BS EN 54-22:2015 | Equivalent |
| DIN EN 54-22:2015-07 | Equivalent |
| EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
| IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
| EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
| IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
| EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
| EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
| EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
| EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
| EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
| IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
| ISO 9001:2015 | Quality management systems — Requirements |
| IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
| EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
| EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
| IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
| IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
| EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
| EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
| EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
| IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.