• Shopping Cart
    There are no items in your cart

I.S. EN 55016-1-4:2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS

Available format(s)

Hardcopy , PDF

Superseded date

12-02-2022

Language(s)

English

Published date

01-01-2010

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

€170.00
Excluding VAT

National Foreword
FOREWORD
INTRODUCTION (to Amendment 1)
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Antennas for measurement of radiated radio disturbance
5 Test sites for measurement of radio disturbance field strength
  for the frequency range of 30 MHz to 1000 MHz
6 Reverberating chamber for total radiated power measurement
7 TEM cells for immunity to radiated disturbance measurement
8 Test sites for measurement of radio disturbance field strength
  for the frequency range 1 GHz to 18 GHz
9 Common mode absorption devices
Annex A (normative) - Parameters of antennas
Annex B (normative) - Monopole (1 m rod) antenna performance
        equations and characterization of the associated antenna
        matching network
Annex C (normative) - Loop antenna system for magnetic field
        induced-current measurements in the frequency range of 9
        kHz to 30 MHz
Annex D (normative) - Construction details for open area test
        sites in the frequency range of 30 MHz to 1000 MHz
Annex E - Void
Annex F (informative) - Basis for 4 dB site acceptability
        criterion
Annex G (informative) - Examples of uncertainty budgets
        for site validation of a COMTS using RSM
        with a calibrated antenna pair
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Describes the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (07/2017)
DocumentType
Standard
Pages
342
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

EN 55016-1-6:2015/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION (CISPR 16-1-6:2014/A1:2017)
CLC/TR 50484:2009 Recommendations for shielded enclosures
IEC 61169-8:2007 Radio-frequency connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristic impedance 50 Ω (type BNC)
CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
EN 55016-2-3:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
CISPR 16-1-5:2014+AMD1:2016 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
EN 55016-1-5:2015/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ (CISPR 16-1-5:2014/A1:2016)
MIL-STD-461 Revision G:2015 REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
CISPR 16-2-3:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
ANSI C63.5 : 2006 ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ)
ETR 273-1-1 : 20001 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT OF RADIATED METHODS OF MEASUREMENT (USING TEST SITES) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1 UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 1: INTRODUCTION
EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
CLC/TR 50481:2009 Recommendations on filters for shielded enclosures
EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)
CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.