I.S. EN 55016-1-4:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS
Hardcopy , PDF
12-02-2022
English
01-01-2010
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
INTRODUCTION (to Amendment 1)
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Antennas for measurement of radiated radio disturbance
5 Test sites for measurement of radio disturbance field strength
for the frequency range of 30 MHz to 1000 MHz
6 Reverberating chamber for total radiated power measurement
7 TEM cells for immunity to radiated disturbance measurement
8 Test sites for measurement of radio disturbance field strength
for the frequency range 1 GHz to 18 GHz
9 Common mode absorption devices
Annex A (normative) - Parameters of antennas
Annex B (normative) - Monopole (1 m rod) antenna performance
equations and characterization of the associated antenna
matching network
Annex C (normative) - Loop antenna system for magnetic field
induced-current measurements in the frequency range of 9
kHz to 30 MHz
Annex D (normative) - Construction details for open area test
sites in the frequency range of 30 MHz to 1000 MHz
Annex E - Void
Annex F (informative) - Basis for 4 dB site acceptability
criterion
Annex G (informative) - Examples of uncertainty budgets
for site validation of a COMTS using RSM
with a calibrated antenna pair
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (07/2017)
|
DocumentType |
Standard
|
Pages |
342
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 55016-1-4:2010/A2:2017 | Identical |
BS EN 55016-1-4 : 2010 | Identical |
UNE-EN 55016-1-4:2011 | Identical |
NEN EN 55016-1-4 : 2010 AMD 2 2017 | Identical |
NF EN 55016-1-4 : 2010 AMD 2 2017 | Identical |
SN EN 55016-1-4 : AMD 2 2005 | Identical |
DIN EN 55016-1-4 : 2013 | Identical |
EN 55016-1-6:2015/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION (CISPR 16-1-6:2014/A1:2017) |
CLC/TR 50484:2009 | Recommendations for shielded enclosures |
IEC 61169-8:2007 | Radio-frequency connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristic impedance 50 Ω (type BNC) |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
EN 55016-2-3:2017 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
CISPR 16-1-5:2014+AMD1:2016 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz |
EN 55016-1-5:2015/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ (CISPR 16-1-5:2014/A1:2016) |
MIL-STD-461 Revision G:2015 | REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT |
IEC 61000-4-20:2010 | Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
ETR 273-1-1 : 20001 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT OF RADIATED METHODS OF MEASUREMENT (USING TEST SITES) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1 UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 1: INTRODUCTION |
EN 61000-4-20:2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES |
CLC/TR 50481:2009 | Recommendations on filters for shielded enclosures |
EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.