I.S. EN 55016-1-5:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ
Hardcopy , PDF
27-10-2020
English
01-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Specifications and validation procedures
for CALTS and REFTS from 5 MHz to
1000 MHz
5 Validation methods for a FAR from
30 MHz to 18 GHz
6 Validation methods for sites used for
the calibration of directive antennas
7 Site validation by comparison of antenna
factors, and application of RSM to evaluate
the uncertainty contribution of a SAC site
Annex A (informative) - CALTS characteristics
and validation
Annex B (informative) - Test antenna considerations
Annex C (informative) - Antenna and SIL theory
Annex D (informative) - Pascal Program used in C.1.4
Annex E (informative) - Validation procedure checklist
Annex F (informative) - Evidence that field taper of VP
site validation method has negligible effect on
measured antenna factor
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6.
DocumentType |
Standard
|
Pages |
218
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 55016-1-5:2015/A1:2017 | Identical |
NEN EN 55016-1-5 : 2015 AMD 1 2017 | Identical |
DIN EN 55016-1-5 : 2015 | Identical |
NF EN 55016-1-5 : 2015 AMD 1 2017 | Identical |
BS EN 55016-1-5:2015 | Identical |
EN 55016-1-6:2015/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION (CISPR 16-1-6:2014/A1:2017) |
EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
IEEE/ANSI C63.7-2015 | American National Standard Guide for Construction of Test Sites for Performing Radiated Emission Measurements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.