1 Scope
2 Normative references
3 Definitions
4 Electromagnetic environment
5 Disturbing phenomena
6 Immunity requirements
7 Testing
8 Documentation for the purchaser/user
Annex A (normative) - Method of measurement of immunity
to radiated magnetic fields, 50 Hz to 10 kHz
Annex B (normative) - Methods of measurement of common
mode immunity for balanced signal and control
ports intended to be connected to cables whose
total length according to the manufacturer's
specification may exceed 10 m; 50 Hz to 10 kHz
Annex C (informative) - Apparatus using infra-red radiation
for open-air transmission purposes
Annex D (informative) - Guidance for test houses on immunity
testing of audio, video, audio-visual and entertainment
lighting control apparatus for professional use
Annex E (informative) - Background information about this
standard
Annex ZZ (informative) - Coverage of Essential Requirements
of EC Directives
Bibliography
Pertains to professional audio, video, audio-visual and entertainment lighting control apparatus as defined in 3.6 intended for use in the environments described in Clause 4.
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
UNE-EN 55103-2:2010 | Identical |
DIN EN 55103-2 : 2010 | Identical |
NBN EN 55103-2 : 2009 | Identical |
SN EN 55103-2 : 2009 | Identical |
NF EN 55103-2 : 2009 | Identical |
NEN EN 55103-2 : 2009 | Identical |
BS EN 55103-2:2009 | Identical |
EN 55103-2:2009 | Identical |
CISPR 20:2006+AMD1:2013 CSV | Sound and television broadcast receivers and associated equipment -Immunity characteristics - Limits and methods of measurement |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 55020:2007/A12:2016 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 20:2006) |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
HD 483.1 : 200S2 | SOUND SYSTEM EQUIPMENT - GENERAL |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 60268-1:1985 | Sound system equipment. Part 1: General |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 55103-1:2009/A1:2012 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR AUDIO, VIDEO, AUDIO-VISUAL AND ENTERTAINMENT LIGHTING CONTROL APPARATUS FOR PROFESSIONAL USE - PART 1: EMISSIONS |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.