FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions and general notes on methods of test
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
23 Pin Hole Test
30 Packaging
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Defines requirements of tape wrapped rectangular copper winding wire of class 240. The insulation comprises one or two wrappings of aromatic polyimide tape. Class 240 is a thermal class requiring a minimum temperature index of 240 and minimum heat shock temperature of 260 deg c.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
28
PublisherName
National Standards Authority of Ireland
Status
Current

ISO 3:1973 Preferred numbers Series of preferred numbers
IEC 60172:2015 Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires
EN 60172:2015 Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires
IEC 60317-0-2:2013 Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire
EN 60317-0-2:2014 Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.