• There are no items in your cart

I.S. EN 60444-1:1999

Current

Current

The latest, up-to-date edition.

MEASUREMENT OF QUARTZ CRYSTAL UNIT PARAMETERS BY ZERO PHASE TECHNIQUE IN A PI-NETWORK - PART 1: BASIC METHOD FOR THE MEASUREMENT OF RESONANCE FREQUENCY AND RESONANCE RESISTANCE OF QUARTZ CRYSTAL UNITS BY ZERO PHASE TECHNIQUE IN A PI-NETWORK

Published date

12-01-2013

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

Sorry this product is not available in your region.

Committees responsible
National foreword
Foreword
1 Scope
2 Definition of resonance frequency
3 Reference plane and shielding box
4 Principle of measurement
5 Measuring circuit
      5.1 The p-network
      5.2 Accessories of the p-network
      5.3 Associated equipment
6 Method of measurement
      6.1 Initial calibration of the p-network
      6.2 Frequency and resistance measurement
Appendix A - Additional information on accuracy
Annex B (normative) updating of some formulae of Appendix A
Figure 1
Figure 2
Figure 3 - Plot showing the phase change from the value at
           25 O versus reference resistor values from 0 to
           100 O AT 10 MHz, 50 MHz, 100 MHz and 200 MHz.
           Measuring circuit according to, Figure 1 page 4
Figure 4 - Reference resistors and shorting blank
Figure 5a
Figure 5a
Figure A.1
Figure A.2
Figure A.3
Figure A.4
Figure A.5
Figure A.6
Figure A.7
Figure A.8 - A typical phase/frequency variation of an
             adjusted p-network with a 25 O reference
             resistor
Figure A.9 - Typical p-network
Figure A.10 - Detail of network assembly
Figure A.11 - Dimensions of contacting plates and earthed
              shield; x indicates position of rod and disk
              centers of p-network
Figure A.12 - Position of the reference resistor with
              respect to the network contacting plates
Figure A.13 - Other design of a p-network

Covers a simple method of measurement of resonance frequency and resonance resistance of quartz crystal units and describes a suitable measuring network for use over the frequency range 1 MHz to 200 MHz.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
PublisherName
National Standards Authority of Ireland
Status
Current

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.