• I.S. EN 60601-2-25:2015

    Current The latest, up-to-date edition.

    MEDICAL ELECTRICAL EQUIPMENT - PART 2-25: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ELECTROCARDIOGRAPHS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2015

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    FOREWORD
    INTRODUCTION
    201.1 Scope, object and related standards
    201.2 Normative references
    201.3 Terms and definitions
    201.4 General requirements
    201.5 General requirements for testing of ME
           EQUIPMENT
    201.6 Classification of ME EQUIPMENT and ME
           SYSTEMS
    201.7 ME EQUIPMENT identification, marking and
           documents
    201.8 Protection against electrical HAZARDS from
           ME EQUIPMENT
    201.9 Protection against MECHANICAL HAZARDS of
           ME EQUIPMENT and ME SYSTEMS
    201.10 Protection against unwanted and excessive
           radiation HAZARDS
    201.11 Protection against excessive temperatures
           and other HAZARDS
    201.12 Accuracy of controls and instruments and protection
           against hazardous outputs
    201.13 HAZARDOUS SITUATIONS and fault conditions
    201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
    201.15 Construction of ME EQUIPMENT
    201.16 ME SYSTEMS
    201.17 Electromagnetic compatibility of ME EQUIPMENT and
           ME SYSTEMS
    202 Electromagnetic compatibility - Requirements and tests
    Annexes
    Annex AA (informative) - Particular guidance and rationale
    Annex BB (informative) - ELECTRODES, their positions,
             identifications and colour codes
    Annex CC (informative) LEADS, their identification and colour
             codes (other than those specified in 201.12.4.102)
    Annex DD (informative) - Polarity of PATIENT LEADS (other than
             those specified in 201.12.4.102)
    Annex EE (informative) - Additional marking of ELECTRODES
    Annex FF (informative) - Definitions and rules for the
             measurement of ELECTROCARDIOGRAMS
    Annex GG (informative) - Calibration and test data sets
    Annex HH (informative) - CTS test atlas
    Bibliography
    Index of defined terms used in this particular standard
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications
    Annex ZZ (informative) - Coverage of Essential
             Requirements of EU Directives

    Abstract - (Show below) - (Hide below)

    Pertains to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTROCARDIOGRAPHS as defined in 201.3.63 intended by themselves or as a part of an ME SYSTEM, for the production of ECG REPORTS for diagnostic purposes, hereinafter referred to as ME EQUIPMENT.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes I.S. EN 60601-2-51. (12/2015) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60601-2-47:2012 Medical electrical equipment - Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems
    IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    IEC 60601-2-2:2017 Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
    IEC 60601-2-27:2011 Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective