I.S. EN 60601-2-27:2014
Current
The latest, up-to-date edition.
MEDICAL ELECTRICAL EQUIPMENT - PART 2-27: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ELECTROCARDIOGRAPHIC MONITORING EQUIPMENT
Hardcopy , PDF
English
01-01-2014
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.8 Protection against electrical HAZARDS from ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME EQUIPMENT
and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
HAZARDS
201.11 Protection against excessive temperatures and other
HAZARDS
201.12 Accuracy of controls and instruments and protection
against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT and
ME SYSTEMS
202 Electromagnetic compatibility - Requirements and tests
208 General requirements, tests and guidance for alarm systems
in medical electrical equipment and medical electrical systems
Annexes
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - Alarm diagrams of Clause
208/IEC 60601-1-8:2006
Bibliography
Index of defined terms used in this particular standard
Annex ZA(normative) - Normative references to
international publications with their
corresponding European publications
Annex ZZ(informative) - Coverage of Essential Requirements
of EC Directives
Pertains to BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTROCARDIOGRAPHIC (ECG) MONITORING EQUIPMENT as defined in 201.3.63 and hereinafter also referred to as ME EQUIPMENT.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
164
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
UNE-EN 60601-2-27:2006 | Identical |
DIN EN 60601-2-27 : 2015 | Identical |
SN EN 60601-2-27 : 2014 | Identical |
EN 60601-2-27:2014 | Identical |
BS EN 60601-2-27:2014 | Identical |
EN 60601-2-25:2015 | Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs |
EN 60601-2-49:2015 | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment |
IEC 60601-1-8:2006+AMD1:2012 CSV | Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60601-2-2:2017 | Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories |
IEC 60601-2-25:2011 | Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs |
AAMI EC13 : 2002 | CARDIAC MONITORS, HEART RATE METERS AND ALARMS |
IEC 60601-2-49:2011 | Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment |
EN 60601-1-8:2007/A11:2017 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2006/A1:2012) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.