I.S. EN 60601-2-49:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PART 2-49: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF MULTIFUNCTION PATIENT MONITORING EQUIPMENT
Hardcopy , PDF
15-09-2023
English
01-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and
documents
201.8 Protection against electrical HAZARDS from ME
EQUIPMENT
201.9 Protection against mechanical hazards of ME
EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
HAZARDS
201.11 Protection against excessive temperatures and
other HAZARDS
201.12 Accuracy of controls and instruments and protection
against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT
and ME SYSTEMS
202 Electromagnetic compatibility - Requirements and tests
208 General requirements, tests and guidance for alarm
systems in medical electrical equipment and medical
electrical systems
Annexes
Annex AA (informative) - General guidance and rationale
Annex BB (informative) - Alarm diagrams of Clause 208/IEC
60601-1-8:2006
ANNEX CC (informative) - Examples of the connection of
the measuring device (MD) for measurement of the
PATIENT LEAKAGE CURRENT and PATIENT
AUXILIARY CURRENT
Bibliography
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Pertains to the basic safety and essential performance requirements of multifunction patient monitoring equipment.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
122
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 60601-2-49:2015 | Identical |
DIN EN 60601-2-49 : 2016 | Identical |
IEC 60601-2-49:2011 | Identical |
BS EN 60601-2-49:2015 | Identical |
UNE-EN 60601-2-49:2016 | Identical |
NF EN 60601-2-49 : 2005 | Identical |
EN 60601-2-34:2014 | Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment |
ISO 80601-2-56:2017 | Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement |
IEC 60601-1-8:2006+AMD1:2012 CSV | Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems |
IEC 62366:2007+AMD1:2014 CSV | Medical devices - Application of usability engineering to medical devices |
IEC 60601-2-34:2011 | Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment |
EN 60601-2-27:2014 | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60601-2-2:2017 | Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories |
IEC 60601-2-27:2011 | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment |
ISO 15223-1:2016 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements |
EN 60601-1-8:2007/A11:2017 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2006/A1:2012) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.