• I.S. EN 61347-2-3:2011

    Current The latest, up-to-date edition.

    LAMP CONTROL GEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2011

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements
    5 General notes on tests
    6 Classification
    7 Marking
    8 Protection against accidental contact with live parts
    9 Terminals
    10 Provisions for earthing
    11 Moisture resistance and insulation
    12 Electric strength
    13 Thermal endurance test for windings
    14 Fault conditions
    15 Protection of associated components
    16 Abnormal conditions
    17 Behaviour of the control gear at end of lamp life
    18 Construction
    19 Creepage distances and clearances
    20 Screws, current-carrying parts and connections
    21 Resistance to heat, fire and tracking
    22 Resistance to corrosion
    Annex A (normative) - Test to establish whether
            a conductive part is a live part which
            may cause an electric shock
    Annex B (normative) - Particular requirements for
            thermally protected lamp control gear
    Annex C (normative) - Particular requirements for
            electronic lamp control gear with
            means of protection against overheating
    Annex D (normative) - Requirements for carrying out
            the heating tests of thermally protected
            lamp control gear
    Annex E (normative) - Use of constant S other than
            4500 in t[w] tests
    Annex F (normative) - Draught-proof enclosure
    Annex G (normative) - Explanation of the derivation of
            the values of pulse voltages
    Annex H (normative) - Tests
    Annex I (normative) - Measurement of high-frequency
            leakage current
    Annex J (normative) - Particular additional safety
            requirements for a.c., a.c./d.c. or d.c.
            supplied electronic control gear for emergency
            lighting
    Annex K (informative) - Components used in the
            asymmetric pulse test circuit
    Annex L (normative) - Information for control gear design
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Describes particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation.

    General Product Information - (Show below) - (Hide below)

    Development Note Together with I.S. EN 61347-1 and parts 2-1, 2-2, 2-4, 2-5, 2-6, 2-7, 2-8 and 2-9 of I.S. EN 61347 supersedes I.S. EN 60920, I.S. EN 60922, I.S. EN 60924, I.S. EN 60926, I.S. EN 60928 and I.S. EN 61046. (07/2005) Supersedes I.S. EN 61347-2-4, I.S. EN 61347-2-5 & I.S. EN 61347-2-6. (11/2011) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply.(01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61547:2009 Equipment for general lighting purposes - EMC immunity requirements
    IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
    EN 60929:2011/A1:2016 AC AND/OR DC-SUPPLIED ELECTRONIC CONTROL GEAR FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS
    IEC 60929:2011+AMD1:2015 CSV AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements
    IEC 61199:2011+AMD1:2012+AMD2:2014 CSV Single-capped fluorescent lamps - Safety specifications
    EN 61347-2-7:2012 Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
    EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
    IEC 61347-2-7:2011+AMD1:2017 CSV Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
    IEC 60598-2-22:2014+AMD1:2017 CSV Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting
    EN 61547:2009 Equipment for general lighting purposes - EMC immunity requirements
    IEC TS 60479-2:2007 Effects of current on human beings and livestock - Part 2: Special aspects
    IEC 61195:1999+AMD1:2012+AMD2:2014 CSV Double-capped fluorescent lamps - Safety specifications
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective