I.S. EN 61558-2-15:2012
Current
The latest, up-to-date edition.
SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - PART 2-15: PARTICULAR REQUIREMENTS AND TESTS FOR ISOLATING TRANSFORMERS FOR THE SUPPLY OF MEDICAL LOCATIONS (IEC 61558-2-15:2011 (EQV))
Hardcopy , PDF
English
01-01-2012
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Ratings
7 Classification
8 Marking and other information
9 Protection against electric shock
10 Change of input voltage setting
11 Output voltage and output current under load
12 No-load output voltage
13 Short-circuit voltage and inrush currents
14 Heating
15 Short-circuit and overload protection
16 Mechanical strength
17 Protection against harmful ingress of
dust, solid objects and moisture
18 Insulation resistance, dielectric strength
and leakage current
19 Construction
20 Components
21 Internal wiring
22 Supply connection and other external flexible
cables or cords
23 Terminals for external conductors
24 Provisions for protective earthing
25 Screws and connections
26 Creepage distances, clearances and distances
through insulation
27 Resistance to heat, fire and tracking
28 Resistance to rusting
Annexes
Annex H - Electronic circuits
Annex L - Routine tests (production tests)
Bibliography
Index of defined terms
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Specifies safety aspects of isolating transformers for the supply of medical locations.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
BS EN 61558-2-15:2012 | Identical |
NF EN 61558-2-15 : 2012 | Identical |
UNE-EN 61558-2-15:2012 | Identical |
IEC 61558-2-15:2011 | Identical |
DIN EN 61558-2-15 : 2012 | Identical |
EN 61558-2-15:2012 | Identical |
SN EN 61558-2-15 : 2001 | Identical |
IEC 60364-7-710:2002 | Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.