I.S. EN 61753-058-2:2013
Current
The latest, up-to-date edition.
FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - PERFORMANCE STANDARD - PART 058-2: SINGLE MODE FIBRE PIGTAILED STYLE OPTICAL POWER LIMITER FOR CATEGORY C - CONTROLLED ENVIRONMENT (IEC 61753-058-2:2013 (EQV))
Hardcopy , PDF
English
01-01-2013
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Tests
4 Test reports
5 Performance requirements
Annex A (normative) - Sample size and product sourcing
requirements
Annex B (normative) - Plimit definition
Annex C (normative) - Response time definition
Annex D (normative) - Maximum allowed power input for optical
limiters, single-mode
Annex E (informative) - Example of dimensions for optical limiters
Annex F (normative) - Testing of optical limiters
Annex ZA (normative) - Normative references to international
Publications with their corresponding
European publications
Covers the minimum initial test and measurement requirements and severities which an optical power limiter needs to satisfy in order to be categorized as meeting the requirements of single mode fibre pigtailed style optical power limiter used in controlled environments.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
EN 61753-058-2:2013 | Identical |
EN 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examination and measurements - Polarization dependent loss in a single-mode fibre optic device |
EN 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-3-4:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 61300-2-17:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
IEC 60869-1:2012 | Fibre optic interconnecting devices and passive components - Fibre optic passive power control devices - Part 1: Generic specification |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
IEC 61300-2-17:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61300-2-14:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
EN 61300-3-7:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-7: Examinations and measurements - Wavelength dependence of attenuation and return loss of single mode components |
IEC 61300-3-7:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-7: Examinations and measurements - Wavelength dependence of attenuation and return loss of single mode components |
EN 61300-1:2016 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance |
IEC 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
IEC 61300-1:2016 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance |
EN 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examinations and measurements - Polarization dependent loss in a single-mode fibre optic device |
EN 60869-1:2013 | Fibre optic interconnecting devices and passive components - Fibre optic passive power control devices - Part 1: Generic specification |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
EN 61300-2-14:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
EN 61300-3-6:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
IEC 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
IEC 61300-2-19:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state) |
EN 61300-3-32 : 2006 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 3-32: EXAMINATIONS AND MEASUREMENTS - POLARIZATION MODE DISPERSION MEASUREMENT FOR PASSIVE OPTICAL COMPONENTS |
EN 61300-2-19:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state) |
IEC 61300-3-32:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-32: Examinations and measurements - Polarization mode dispersion measurement for passive optical components |
EN 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.