I.S. EN 62271-201:2014
Current
The latest, up-to-date edition.
HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
Hardcopy , PDF
English
01-01-2014
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide to the selection of switchgear
and controlgear
9 Information to be given with enquiries,
tenders and orders
10 Transport, storage, installation, operation
and maintenance
11 Safety
12 Influence of the product on the environment
Annex AA (normative) - Internal arc fault - Method
to verify the internal arc classification (IAC)
Annex BB (normative) - Partial discharge measurement
Annex CC (informative) - Regional deviations
Annex DD (normative) - Humidity test
Annex EE (informative) - Protection categories
Annex FF (informative) - List of symbols and abbreviations
used in IEC 62271-201
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines requirements for prefabricated solid-insulation enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor installation and for service frequencies up to and including 60 Hz.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
212
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
EN 62271-201:2014 | Identical |
NF EN 62271-201 : 2014 | Identical |
DIN EN 62271-201 : 2015-03 | Identical |
UNE-EN 62271-201:2015 | Identical |
NBN EN 62271-201 : 2014 | Identical |
BS EN 62271-201:2014 | Identical |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 62271-106:2011 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60724:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 62271-105:2012 | High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 62271-102:2002/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013) |
IEC 60909-0:2016 | Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents |
IEEE 400.2-2013 REDLINE | IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
EN 62271-103:2011 | High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
IEC TS 62271-304:2008 | High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and includuing 52 kV to be used in severe climatic conditions |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
EN 62271-106:2011 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
IEC 62271-103:2011 | High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEEE C37.20.7-2007 REDLINE | IEEE Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60059:1999+AMD1:2009 CSV | IEC standard current ratings |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 62271-105:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-105:2012) |
EN 50187 : 96 AC 96 | GAS-FILLED COMPARTMENTS FOR A.C. SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV | High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-