I.S. EN 62271-204:2011
Current
The latest, up-to-date edition.
HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-204:2011 (EQV))
Hardcopy , PDF
English
01-01-2011
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide to the selection of GIL
9 Information to be given with enquiries, tenders and orders
10 Transport, storage, installation, operation and maintenance
11 Safety
12 Influence of the product on the environment
Annex A (informative) - Estimation of continuous current
Annex B (informative) - Earthing
Annex C (normative) - Long-term testing of buried installations
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Applicable to rigid HV gas-insulated transmission lines (GIL) in which the insulation is obtained, at least partly, by a non-corrosive insulating gas, other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, and for service frequencies up to and including 60 Hz.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
SupersededBy |
Standards | Relationship |
EN 62271-204:2011 | Identical |
IEC 62271-204:2011 | Identical |
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
EN 60229:2008 | Electric cables - Tests on extruded oversheaths with a special protective function |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
EN 60376:2005 | Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
CLC/TR 62271-303:2009 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 303: USE AND HANDLING OF SULPHUR HEXAFLUORIDE (SF[6]) |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 62271-203:2012 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 60480:2004 | Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use |
IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC TR 60943:1998+AMD1:2008 CSV | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
IEC 60287-3-1:2017 | Electric cables - Calculation of the current rating - Part 3-1: Operating conditions - Site reference conditions |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60229:2007 | Electric cables - Tests on extruded oversheaths with a special protective function |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC TS 60479-2:2007 | Effects of current on human beings and livestock - Part 2: Special aspects |
IEC 60287-1-1:2006+AMD1:2014 CSV | Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General |