I.S. EN 80601-2-58:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PART 2-58: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LENS REMOVAL DEVICES AND VITRECTOMY DEVICES FOR OPHTHALMIC SURGERY
Hardcopy , PDF
14-09-2019
English
01-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME
EQUIPMENT
201.6 Classification of ME EQUIPMENT and
ME SYSTEMS
201.7 ME EQUIPMENT identification, marking
and documents
201.8 Protection against electrical HAZARDS from
ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS
of ME EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
radiation HAZARDS
201.11 Protection against excessive temperatures and
other HAZARDS
201.12 Accuracy of controls and instruments and protection
against hazardous outputs
201.13 Hazardous situations and fault conditions for
ME EQUIPMENT
201.14 PROGRAMMABLE ELECTRICAL MEDICAL
SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT
and ME SYSTEMS
202 Electromagnetic compatibility - Requirements and tests
Annex C (informative) - Guide to marking and labelling
requirements for ME EQUIPMENT and ME SYSTEMS
Annex AA (informative) - Particular guidance and rationale
Bibliography
Index of defined terms
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Pertains to the basic safety and essential performance of lens removal devices and vitrectomy devices for ophthalmic surgery and associated accessories that can be connected to this medical electrical equipment, hereafter referred to as ME equipment.
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 80601-2-58:2015 | Identical |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
ISO 11607-2:2006 | Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes |
ISO 15752:2010 | Ophthalmic instruments Endoilluminators Fundamental requirements and test methods for optical radiation safety |
IEC 60825-1:2014 | Safety of laser products - Part 1: Equipment classification and requirements |
IEC 61847:1998 | Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics |
IEC 60601-2-22:2007+AMD1:2012 CSV | Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
EN 60601-2-22:2013 | Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60601-2-2:2017 | Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories |
ISO/TR 16142:2006 | Medical devices Guidance on the selection of standards in support of recognized essential principles of safety and performance of medical devices |
ISO 15004-2:2007 | Ophthalmic instruments Fundamental requirements and test methods Part 2: Light hazard protection |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
ISO 17664:2017 | Processing of health care products Information to be provided by the medical device manufacturer for the processing of medical devices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.