I.S. EN IEC 60601-2-2:2018
Current
The latest, up-to-date edition.
MEDICAL ELECTRICAL EQUIPMENT - PART 2-2: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HIGH FREQUENCY SURGICAL EQUIPMENT AND HIGH FREQUENCY SURGICAL ACCESSORIES
Hardcopy , PDF
English - French
05-06-2018
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.8 Protection against electrical HAZARDS from
ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME
EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
radiation HAZARDS
201.11 Protection against excessive temperatures
and other HAZARDS
201.12 Accuracy of controls and instruments and
protection against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions for ME EQUIPMENT
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS
202 * ELECTROMAGNETIC DISTURBANCES - Requirements and tests
208 General requirements, tests and guidance for alarm systems
in medical electrical equipment and medical electrical systems
Annexes
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - ELECTROMAGNETIC DISTURBANCES
created by HF SURGICAL EQUIPMENT
Bibliography
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Specify to the basic safety and essential performance of HF surgical equipment and HF surgical accessories.
Committee |
SC 62D
|
DevelopmentNote |
Supersedes I.S. EN 60601-2-2. For CENELEC adoptions of IEC publication, please check www.iec.ch to be sure that you have any corrigenda that may apply. (06/2018)
|
DocumentType |
Standard
|
ISBN |
978-2-8322-4008-3
|
Pages |
200
|
ProductNote |
The date of any NSAI previous adoption may not match the date of its original CEN/CENELEC document.
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 60601-2-2:2017 | Identical |
EN IEC 60601-2-2:2018 | Identical |
IEC 60601-1-8:2006+AMD1:2012 CSV | Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems |
IEC 60601-2-18:2009 | Medical electrical equipment - Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment |
CENELEC GUIDE 29 : 2007 | TEMPERATURES OF HOT SURFACES LIKELY TO BE TOUCHED GUIDANCE DOCUMENT FOR TECHNICAL COMMITTEES AND MANUFACTURERS |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 60601-2-4:2010 | Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
AAMI HF18 : 2001 ERRATA 2001 | ELECTROSURGICAL DEVICES |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60601-1-8:2007/A11:2017 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2006/A1:2012) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.