I.S. EN ISO 18778:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
RESPIRATORY EQUIPMENT - INFANT MONITORS - PARTICULAR REQUIREMENTS
Hardcopy , PDF
29-05-2023
English
01-01-2009
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements and general requirements for tests
5 Classification
6 Identification, marking and documents
7 Power input
8 Basic safety categories
9 Removable protective means
10 Environmental conditions
13 General
14 Requirements related to classification
15 Limitation of voltage and/or energy
16 Enclosures and protective covers
17 Separation
18 Protective earthing, functional earthing and potential
equalization
19 Continuous leakage currents and patient auxiliary currents
20 Dielectric strength
21 Mechanical strength
22 Moving parts
23 Surfaces, corners and edges
24 Stability in normal use
25 Expelled parts
26 Vibration and noise
27 Pneumatic and hydraulic power
28 Suspended masses
29 X-Radiation
30 Alpha, beta, gamma, neutron radiation and other particle
radiation
31 Microwave radiation
32 Light radiation (including lasers)
33 Infrared radiation
34 Ultraviolet energy
35 Acoustical energy (including ultrasonics)
36 Electromagnetic Compatibility
37 Locations and basic requirements
38 Marking and accompanying documents
39 Common requirements for category AP and category APG
equipment
40 Requirements and tests for category AP equipment, parts
and components thereof
41 Requirements and tests for category APG equipment, parts
and components thereof
42 Excessive temperatures
43 Fire prevention
44 Overflow, spillage, leakage, humidity, ingress of liquids,
cleaning, sterilization, disinfection and compatibility
45 Pressure vessels and parts subject to pressure
46 Human errors
47 Electrostatic charges
48 Biocompatibility
49 Interruption of the power supply
50 Accuracy of operating data
51 Protection against hazardous output
52 Abnormal operation and fault conditions
53 Environmental tests
54 General
55 Enclosures and covers
56 Components and general assembly
57 Mains parts, components and layout
58 Protective earthing - Terminals and connections
59 Construction and layout
101 Additional requirements
Annex AA (informative) - Rationale
Annex BB (informative) - Environmental aspects
Annex CC (informative) - Index of defined terms
Annex ZA (Informative) - Relationship between this
European Standard and the Essential
Requirements of EU Directive 93/42/EEC
Bibliography
Describes requirements for the safety and essential performance of monitors used to detect apparent life-threatening events in sleeping or resting children under three years of age.
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ONORM EN ISO 18778 : 2009 | Identical |
EN ISO 18778:2009 | Identical |
BS EN ISO 18778:2009 | Identical |
NBN EN ISO 18778 : 2009 | Identical |
NS EN ISO 18778 : 2009 | Identical |
NF EN ISO 18778 : 2009 | Identical |
UNE-EN ISO 18778:2009 | Identical |
UNI EN ISO 18778 : 2009 | Identical |
DIN EN ISO 18778:2009-08 | Identical |
NEN EN ISO 18778 : 2009 | Identical |
ISO 18778:2005 | Identical |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
ISO 15001:2010 | Anaesthetic and respiratory equipment Compatibility with oxygen |
IEC 60601-1-6:2010+AMD1:2013 CSV | Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability |
IEC 60601-2-23:2011 | Medical electrical equipment - Part 2-23: Particular requirements for the basic safety and essential performance of transcutaneous partial pressure monitoring equipment |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 1041:2008+A1:2013 | Information supplied by the manufacturer of medical devices |
EN 71-1:2014 | Safety of toys - Part 1: Mechanical and physical properties |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60601-2-27:2011 | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment |
NFPA 53M : 1990 | FIRE HAZARDS IN OXYGEN-ENRICHED ATMOSPHERES |
ISO 9919:2005 | Medical electrical equipment Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
ISO 4135:2001 | Anaesthetic and respiratory equipment Vocabulary |
EN 980:2008 | Symbols for use in the labelling of medical devices |
EN 60601-1-8:2007/A11:2017 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2006/A1:2012) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.