I.S. EN ISO 25539-1:2017
Current
The latest, up-to-date edition.
CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 1: ENDOVASCULAR PROSTHESES (ISO 25539-1:2017)
Hardcopy , PDF
English
01-01-2017
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements for endovascular system
5 Intended performance
6 Design attributes
7 Materials
8 Design evaluation
9 Post-market surveillance
10 Manufacturing
11 Sterilization
12 Packaging
Annex A (informative) - Relationship between testing
requirements and device attributes and potential
failure modes
Annex B (informative) - Description of clinical and
device effects of failure
Annex C (informative) - Bench and analytical tests
Annex D (informative) - Test methods
Bibliography
Annex ZA (informative) - Relationship between this
European Standard and the Essential Requirements
of EU Directive 93/42/EEC [OJ L 169] aimed to be
covered
Describes requirements for the evaluation of endovascular systems (prostheses and delivery systems) and requirements with respect to nomenclature, design attributes and information supplied by the manufacturer based upon current medical knowledge.
DevelopmentNote |
Supersedes I.S. EN 14299. (12/2008) Supersedes I.S. EN 12006-3. (03/2011)
|
DocumentType |
Standard
|
Pages |
148
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
ISO 25539-1:2017 | Identical |
EN ISO 25539-1:2017 | Identical |
ISO 11070:2014 | Sterile single-use intravascular introducers, dilators and guidewires |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
EN 556:1994 + A1:1998 | STERILIZATION OF MEDICAL DEVICES - REQUIREMENTS FOR TERMINALLY-STERILIZED MEDICAL DEVICES TO BE LABELLED "STERILE" |
ISO 10993-3:2014 | Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity |
ISO 10993-4:2017 | Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood |
ISO 10993-16:2017 | Biological evaluation of medical devices — Part 16: Toxicokinetic study design for degradation products and leachables |
ISO/TS 10993-20:2006 | Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices |
EN ISO 14937:2009 | Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices (ISO 14937:2009) |
EN ISO 10993-5:2009 | Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity (ISO 10993-5:2009) |
EN ISO 10993-2:2006 | Biological evaluation of medical devices - Part 2: Animal welfare requirements (ISO 10993-2:2006) |
ISO 14160:2011 | Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical devices |
ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
EN ISO 10993-11:2009 | Biological evaluation of medical devices - Part 11: Tests for systemic toxicity (ISO 10993-11:2006) |
ISO 10993-13:2010 | Biological evaluation of medical devices — Part 13: Identification and quantification of degradation products from polymeric medical devices |
ISO 7198:2016 | Cardiovascular implants and extracorporeal systems — Vascular prostheses — Tubular vascular grafts and vascular patches |
ASTM F 2503 : 2013 : REDLINE | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ISO/TR 37137:2014 | Cardiovascular biological evaluation of medical devices — Guidance for absorbable implants |
ISO/TS 17665-2:2009 | Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1 |
ISO 17475:2005 | Corrosion of metals and alloys — Electrochemical test methods — Guidelines for conducting potentiostatic and potentiodynamic polarization measurements |
EN ISO 10993-17:2009 | Biological evaluation of medical devices - Part 17: Establishment of allowable limits for leachable substances (ISO 10993-17:2002) |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
EN ISO 10993-13:2010 | Biological evaluation of medical devices - Part 13: Identification and quantification of degradation products from polymeric medical devices (ISO 10993-13:2010) |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
EN ISO 10993-9:2009 | Biological evaluation of medical devices - Part 9: Framework for identification and quantification of potential degradation products (ISO 10993-9:2009) |
ISO 10993-2:2006 | Biological evaluation of medical devices — Part 2: Animal welfare requirements |
ASTM F 3044 : 2014 | Test Method for Standard Test Method for Evaluating the Potential for Galvanic Corrosion for Medical Implants |
ISO 5840-1:2015 | Cardiovascular implants Cardiac valve prostheses Part 1: General requirements |
EN ISO 10993-10:2013 | Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization (ISO 10993-10:2010) |
EN ISO 10993-7 : 2008 COR 2009 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS (ISO 10993-7:2008/COR 1:2009) |
EN ISO 10993-4:2017 | Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood (ISO 10993-4:2017) |
ASTM G 71 : 1981 | GUIDE FOR CONDUCTING AND EVALUATING GALVANIC CORROSION TESTS IN ELECTROLYTES |
CEN ISO/TS 17665-2:2009 | Sterilization of health care products - Moist heat - Part 2: Guidance on the application of ISO 17665-1 (ISO/TS 17665-2:2009) |
EN ISO 11135:2014 | Sterilization of health-care products - Ethylene oxide - Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 11135:2014) |
EN ISO 10993-3:2014 | Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity (ISO 10993-3:2014) |
ISO 10993-14:2001 | Biological evaluation of medical devices — Part 14: Identification and quantification of degradation products from ceramics |
ASTM F 3067 : 2014 | Guide for Radial Loading of Balloon Expandable and Self Expanding Vascular Stents |
ISO 14630:2012 | Non-active surgical implants — General requirements |
ISO/TS 17137:2014 | Cardiovascular implants and extracorporeal systems Cardiovascular absorbable implants |
ISO 10993-18:2005 | Biological evaluation of medical devices Part 18: Chemical characterization of materials |
EN ISO 10993-6:2016 | Biological evaluation of medical devices - Part 6: Tests for local effects after implantation (ISO 10993-6:2016) |
ISO/TS 10993-19:2006 | Biological evaluation of medical devices Part 19: Physico-chemical, morphological and topographical characterization of materials |
ASTM F 2052 : 2015 : REDLINE | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment |
EN ISO 11137-2:2015 | Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose (ISO 11137-2:2013) |
ISO 10993-10:2010 | Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization |
ISO 10993-11:2017 | Biological evaluation of medical devices — Part 11: Tests for systemic toxicity |
ISO 11137-3:2017 | Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
ASTM F 2213 : 2017 : REDLINE | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ISO 11137-2:2013 | Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
EN ISO 10993-18:2009 | Biological evaluation of medical devices - Part 18: Chemical characterization of materials (ISO 10993-18:2005) |
ISO 10555-1:2013 | Intravascular catheters — Sterile and single-use catheters — Part 1: General requirements |
EN ISO 11137-1:2015 | Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 11137-1:2006, including Amd 1:2013) |
ASTM F 2942 : 2013 | Standard Guide for <emph type="bdit">in vitro</emph> Axial, Bending, and Torsional Durability Testing of Vascular Stents |
EN ISO 14971:2012 | Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01) |
ISO 10993-9:2009 | Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products |
EN ISO 10993-12:2012 | Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012) |
ISO 14155:2011 | Clinical investigation of medical devices for human subjects Good clinical practice |
ASTM F 2914 : 2012 | Standard Guide for Identification of Shelf-life Test Attributes for Endovascular Devices |
EN ISO 17665-1:2006 | Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 17665-1:2006) |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
ISO 594-2:1998 | Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings |
ISO 15223-1:2016 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements |
ISO 594-1:1986 | Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 1: General requirements |
EN ISO 10993-15:2009 | Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys (ISO 10993-15:2000) |
EN ISO 10993-14:2009 | Biological evaluation of medical devices - Part 14: Identification and quantification of degradation products from ceramics (ISO 10993-14:2001) |
EN ISO 11137-3:2017 | Sterilization of health care products - Radiation - Part 3: Guidance on dosimetric aspects of development, validation and routine control (ISO 11137-3:2017) |
EN ISO 14160:2011 | Sterilization of health care products - Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives - Requirements for characterization, development, validation and routine control of a sterilization process for medical devices (ISO 14160:2011) |
ISO 10993-6:2016 | Biological evaluation of medical devices Part 6: Tests for local effects after implantation |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
EN ISO 14630:2012 | Non-active surgical implants - General requirements (ISO 14630:2012) |
ASTM F 640 : 2012 : REDLINE | Standard Test Methods for Determining Radiopacity for Medical Use |
ISO 10555-4:2013 | Intravascular catheters — Sterile and single-use catheters — Part 4: Balloon dilatation catheters |
ISO 16429:2004 | Implants for surgery — Measurements of open-circuit potential to assess corrosion behaviour of metallic implantable materials and medical devices over extended time periods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.