I.S. HD 483.5 S2:1995
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
SOUND SYSTEM EQUIPMENT - PART 5: LOUDSPEAKERS
Hardcopy , PDF
19-02-1999
English
01-01-1995
FOREWORD
PREFACE
1 Scope
2 Object
SECTION ONE - GENERAL
3 Conditions
3.1 General conditions
3.2 Conditions for the measurement
4 Test signals
4.1 Sinusoidal signal
4.2 Broadband noise signal
4.3 Narrow band noise signal
5 Acoustical environment
5.1 Free-field conditions
5.2 Half space free-field conditions
5.3 Diffuse sound field conditions
6 Unwanted acoustical and electrical noise
7 Positioning of loudspeaker and measuring microphone
7.1 Measuring distance under free-field and half
space free-field conditions
7.2 Positioning of loudspeaker in diffuse field conditions
8 Measuring equipment
9 Accuracy of acoustical measurement
10 Mounting of loudspeakers
10.1 Mounting and acoustical loading of drive units
10.2 Mounting and acoustical loading of loudspeaker system
11 Standard baffle
12 Preconditioning
SECTION TWO - CHARACTERISTICS TO BE SPECIFIED AND THE
RELEVANT METHODS OF MEASUREMENT
13 Type description
13.1 Loudspeaker drive units
13.2 Loudspeaker system
14 Marking of terminals and controls
15 Reference plane, reference point and reference axis
15.1 Reference plane
15.2 Reference point
15.3 Reference axis
16 Impedance and derivative characteristics
16.1 Rated impedance
16.2 Impedance curve
16.3 Total Q-factor (Q[1])
16.4 Equivalent air volume of a loudspeaker drive unit
compliance (V[as])
17 Input voltage
17.1 Short term maximum input voltage
17.2 Long term maximum input voltage
17.3 Rated sinusoidal voltage
17.4 Rated noise voltage
18 Input electrical power
18.1 Short term maximum power
18.2 Long term maximum power
18.3 Rated sinusoidal power
18.4 Rated noise power
19 Frequency characteristics
19.1 Rated frequency range
19.2 Resonance frequency
19.3 Tuning frequency of a bass reflex or passive radiator
loudspeaker system
20 Sound pressure under free field and half space free field
conditions
20.1 Sound pressure in a stated frequency band
20.2 Sound pressure level in stated frequency band
20.3 Characteristic sensitivity in a stated frequency band
20.4 Characteristic sensitivity level in a stated frequency band
20.5 Mean sound pressure in a stated frequency band
20.6 Mean sound pressure level in a stated frequency band
21 Response under free-field and half space free-field conditions
21.1 Frequency response
21.2 Effective frequency range
21.3 Transfer function
22 Output power (acoustic power)
22.1 Acoustic power in a frequency band
22.2 Mean acoustic power in frequency band
22.3 Efficiency in a frequency band
22.4 Mean efficiency in a frequency band
23 Directional characteristics
23.1 Directional response pattern
23.2 Radiation angle
23.3 Directivity index
24 Amplitude non-linearity
24.1 Introduction
24.2 Total harmonic distortion
24.3 Harmonic distortion of the n[th] order
24.4 Characteristic harmonic distortion
24.5 Total noise distortion
24.6 Noise distortion of the n[th] order
24.7 Characteristic noise distortion
24.8 Modulation distortion of the n[th] order
24.9 Characteristic modulation distortion of the n[th] order
24.10 Difference frequency distortion
24.11 Noise intermodulation distortion
SECTION THREE - OTHER CHARACTERISTICS AND CLASSIFICATION
25 Interfering stray field
26 Rated ambient conditions
27 Physical characteristics
27.1 Dimensions
27.2 Weight
27.3 Cable assemblies
28 Design data
29 Classification of the characteristics to be specified
FIGURES
ANNEX ZA (normative) OTHER INTERNATIONAL PUBLICATIONS QUOTED
IN THIS STANDARD WITH THE REFERENCES OF THE RELEVANT
EUROPEAN PUBLICATIONS
Applicable to sound system loudspeakers, treated as entirely passive elements. Loudspeakers with built-in amplifiers are excluded.
DocumentType |
Standard
|
Pages |
94
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
HD 483.5 : 200S2 | Identical |
IEC 60268-5:2003+AMD1:2007 CSV | Identical |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
IEC 60268-12:1987 | Sound system equipment. Part 12: Application of connectors for broadcast and similar use |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
EN ISO 3741:2010 | Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods for reverberation test rooms (ISO 3741:2010) |
IEC 60268-14:1980 | Sound system equipment. Part 14: Circular and ellipticalloudspeakers; outer frame diameters and mounting dimensions |
HD 483.11 : 200S3 | SOUND SYSTEM EQUIPMENT - APPLICATION OF CONNECTORS FOR THE INTERCONNECTION OF SOUND SYSTEM COMPONENTS |
HD 483.12 : 200S2 | SOUND SYSTEM EQUIPMENT - APPLICATION OF CONNECTORS FOR BROADCAST AND SIMILAR USE |
IEC 60225:1966 | Octave, half-octave and third-octave band filters intended for the analysis of sounds and vibrations |
EN ISO 3744:2010 | Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane (ISO 3744:2010) |
IEC 60263:1982 | Scales and sizes for plotting frequency characteristics and polar diagrams |
HD 483.1 : 200S2 | SOUND SYSTEM EQUIPMENT - GENERAL |
IEC 60268-1:1985 | Sound system equipment. Part 1: General |
EN 60651:1994/A2:2001 | SOUND LEVEL METERS (IEC 60651:1979/A2:2000) |
HD 483.2 : 200S2 | SOUND SYSTEM EQUIPMENT - EXPLANATION OF GENERAL TERMS AND CALCULATION METHODS |
IEC 60268-11:1987 | Sound system equipment. Part 11: Application of connectors for the interconnection of sound system components |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.