I.S. HD 60364-6:2007

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 6: VERIFICATION

Available format(s)

Hardcopy , PDF

Withdrawn date

01-06-2019

Language(s)

English

Published date

17-03-2017

€149.00
Excluding VAT

6.1 Scope
6.2 Normative references
6.3 Definitions
61 Initial verification
    61.1 General
    61.2 Inspection
    61.3 Testing
         61.3.1 General
         61.3.2 Continuity of conductors
         61.3.3 Insulation resistance of the electrical
                 installation
         61.3.4 Protection by SELV, PELV or by electrical
                 separation
         61.3.5 Insulation resistance/impedance of floors
                 and walls
         61.3.6 Protection by automatic disconnection of
                 the supply
         61.3.7 Additional protection
         61.3.8 Polarity test
         61.3.9 Check of phase sequence
         61.3.10 Functional test
         61.3.11 Voltage drop
    61.4 Reporting for initial verification
 62 Periodic verification
    62.1 General
    62.2 Frequency of periodic verification
    62.3 Reporting for periodic verification
Annex A (informative) - Method for measuring the insulation
        resistance/impedance of floors and walls to earth or
        to the protective conductor
      A.1 General
      A.2 Test method for measuring the impedance of floors
          and walls with a.c. voltage
      A.3 Test electrode 1
      A.4 Test electrode 2
Annex B (informative) - Method B1, B2 and B3
      B.1 Method B1 - Measurement of earth electrode resistance
      B.2 Method B2 - Measurement of the fault loop impedance
      B.3 Method B3 - Measurement of earth loop resistance with
                      current clamps
Annex C (informative) - Guide on the application of the rules
        of clause 61: Initial verification
Annex D (informative) - Example of a diagram suitable for the
        evaluation of the voltage drop
Annex E (informative) - Recommendation for electrical equipment,
        which is being re-used in electrical installations
Annex F (informative) - Description of the installation for
        verification
Annex G (informative) - Form for inspection of electrical
        installations (see examples in G.2)
Annex H (informative) - Reporting for verification
Annex ZA (normative) - Special national conditions
Annex ZB (informative) - A-deviations
Annex I (informative) - Correspondence between IEC 60364-6-61:2001
        and IEC 60364-6:2006
Bibliography

Provides requirements for initial and periodic verification of an electrical installation.

DevelopmentNote
Supersedes I.S. HD 384.6.61. (03/2007)
DocumentType
Standard
Pages
125
PublisherName
National Standards Authority of Ireland
Status
Withdrawn
Supersedes

IEC 60364-5-54:2011 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors
IEC 60364-4-43:2008 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
EN 60238 : 2004 AMD 2 2011 EDISON SCREW LAMPHOLDERS (IEC 60238:2004/A2:2011)
IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control
IEC 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
IEC 61557-2:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
EN 60079-17:2014 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
IEC 60364-4-42:2010+AMD1:2014 CSV Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects
EN 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.