IEC 60079-10-2:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
Hardcopy , PDF
English - French
16-01-2015
29-06-2026
IEC 60079-10-2:2015 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas. In this standard, explosive dust atmospheres and combustible dust layers are treated separately. In Clause 4, area classification for explosive dusts clouds is described, with dust layers acting as one of the possible sources of release. In Clause 7 other general considerations for dust layers are described. The examples in this standard are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers. The principles of this standard can also be followed when combustible fibres or flyings might cause a hazard. This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions. Please refer to the foreword of the document for a detailed listing of the significant technical changes from the previous edition. Keywords: explosive dust atmospheres, combustible dust layers, ignition hazards
| Committee |
TC 31/SC 31J
|
| DocumentType |
Standard
|
| Pages |
56
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| EN 60079-10-2:2015 | Identical |
| AS/NZS 60079.10.2:2016 | Identical |
| UNE-EN 60079-10-2:2016 | Identical |
| BS EN 60079-10-2:2015 | Identical |
| DIN EN 60079-10-2:2015-10 | Identical |
| VDE 0165-102:2015-10 | Identical |
| CSA C22.1:21 | Canadian Electrical Code, Part I (25th Edition), Safety Standard for Electrical Installations |
| CEI EN IEC 61936-1:2024 | Power installations exceeding 1 kV AC and 1,5 kV DC Part 1: AC |
| CAN/CSA-C22.2 NO. 60079-18:16 (R2021) | Explosive atmospheres - Part 18: Equipment protection by encapsulation \"m\" (Adopted IEC 60079-18:2014, fourth edition, 2014-12, with Canadian deviations) |
| PIP ELEHA01:2021 | Guideline for Determining Electrical Area Classification |
| CEI EN IEC 60079-28:2026 | Explosive atmospheres –Part 28: Protection of equipment and transmission systems using optical radiation |
| AS 62282.3.300:2021 | Fuel cell technologies Stationary fuel cell power systems - Installation (IEC 62282-3-300:2012 (ED.1.0), MOD) |