• IEC 60099-5:2018 RLV

    Current The latest, up-to-date edition.

    Surge arresters - Part 5: Selection and application recommendations

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  19-01-2018

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General principles for the application of surge arresters
    5 Surge arrester fundamentals and applications issues
    6 Insulation coordination and surge arrester applications
    7 Surge arresters for special applications
    8 Asset management of surge arresters
    Annex A (informative) - Determination of temporary
            overvoltages due to earth faults
    Annex B (informative) - Current practice
    Annex C (informative) - Arrester modelling techniques for
            studies involving insulation coordination and energy
            requirements
    Annex D (informative) - Diagnostic indicators of metal-oxide
            surge arresters in service
    Annex E (informative) - Typical data needed from arrester
            manufacturers for proper selection of surge arresters
    Annex F (informative) - Typical maximum residual voltages
            for metal-oxide arresters without gaps according to
            IEC 60099-4
    Annex G (informative) - Steepness reduction of incoming
            surge with additional line terminal surge capacitance
    Annex H (informative) - Comparison of the former energy
            classification system based on line discharge
            classes and the present classification system
            based on thermal energy ratings for operating duty
            tests and repetitive charge transfer ratings for
            repetitive single event energies
    Annex I (informative) - Estimation of arrester cumulative
            charges and energies during line switching
    Annex J (informative) - End of life and replacement of
            old gapped SiC-arresters
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 60099-5:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.

    IEC 60099-5:2018 provides information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV. It applies to gapless metal-oxide surge arresters as defined in IEC 60099-4, to surge arresters containing both series and parallel gapped structure – rated 52 kV and less as defined in IEC 60099-6 and metal-oxide surge arresters with external series gap for overhead transmission and distribution lines (EGLA) as defined in IEC 60099-8. In Annex J, some aspects regarding the old type of SiC gapped arresters are discussed. Surge arrester residual voltage is a major parameter to which most users have paid a lot of attention to when selecting the type and rating. Typical maximum residual voltages are given in Annex F. It is likely, however, that for some systems, or in some countries, the requirements on system reliability and design are sufficiently uniform, so that the recommendations of the present standard may lead to the definition of narrow ranges of arresters. The user of surge arresters will, in that case, not be required to apply the whole process introduced here to any new installation and the selection of characteristics resulting from prior practice may be continued. Annexes H and I present comparisons and calculations between old line discharge classification and new charge classification. This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition regarding the new surge arrester classification introduced in IEC 60099-4:2014:
    a) Expanded discussion of comparison between the old and new classification and how to calculate or estimate the corresponding charge for different stresses.
    b) New annexes dealing with:
    - Comparison between line discharge classes and charge classification
    - Estimation of arrester cumulative charges and energies during line switching

    Keywords: selection and application of surge arrestors, nominal voltages above 1 kV

    General Product Information - (Show below) - (Hide below)

    Committee TC 37
    Development Note Also available in CD-ROM format. Stability date: 2020. (01/2018)
    Document Type Redline
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    IEC TR 60071-4:2004 Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks
    IEC TR 62271-300:2006 High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers
    IEC 60099-6:2002 Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less
    IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
    IEC 60099-8:2017 Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
    IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective