FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General requirement
5 General conditions for tests
6 Standard ratings
7 Classification
8 Marking
9 Dimensions
10 Protection against electric shock
11 Terminals
12 Provision for earthing
13 Construction
14 Switched lampholders
15 Moisture resistance, insulation resistance and
electric strength
16 Mechanical strength
17 Screws, current-carrying parts and connections
18 Creepage distances and clearances
19 Normal operation
20 General resistance to heat
21 Resistance to heat, fire and tracking
22 Resistance to excessive residual stresses (season
cracking) and to rusting
Annex A (normative) - Season cracking/corrosion test
Annex B (informative) - Guidance for requirements in
IEC 61058-1 applicable to switches in lampholders
Annex C (informative) - Guidance for special requirements
in appliance standards - Household and similar
electrical appliances
Annex D (informative) - Schedule of amended subclauses
containing more serious/critical requirements
which require products to be retested
Bibliography
IEC 60238:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60238:2016 applies to lampholders with Edison thread E14, E27 and E40, designed for connection to the supply of lamps and semi-luminaires only. It also applies to switched-lampholders for use in AC circuits only, where the working voltage does not exceed 250 V r.m.s. This ninth edition cancels and replaces the eighth edition published in 2004, Amendment 1: 2008 and Amendment 2:2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Addition of a pull test for certain E5 and E10 lampholders.
b) Annex D listing amended requirements/clauses which require products to be retested.
Committee |
TC 34/SC 34B
|
DevelopmentNote |
Stability Date: 2018. (07/2016)
|
DocumentType |
Redline
|
Pages |
240
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60061-3:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges |
IEC 60335-2-24:2010+AMD1:2012+AMD2:2017 CSV | Household and similar electrical appliances - Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60061-2:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60399:2004+AMD1:2008 CSV | Barrel thread for lampholders with shade holder ring |
IEC 60352-1:1997 | Solderless connections - Part 1: Wrapped connections - General requirements, test methods and practical guidance |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60061-4:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 4: Guidelines and general information |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 4046-4:2002 | Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60630:2005 CSV | Maximum lamp outlines for incandescent lamps |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.