IEC 60331-2:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
09-06-2020
English - French
19-05-2009
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test environment
5 Test apparatus
6 Test specimen (electric power and control cables
with rated voltage up to and including
600 V/1000 V)
7 Test procedure (electric power and control cables
with rated voltage up to and including 600 V/1000 V)
8 Performance requirements (electric power and control
cables with rated voltage up to and including 600 V/1000 V)
9 Retest procedure
10 Test report (electric power and control cables with rated
voltage up to and including 600 V/1000 V)
11 Cable marking
Annex A (normative) - Verification procedure for the source
of heat
Annex B (informative) - Guidance on the choice of
recommended test apparatus
Bibliography
IEC 60331-2:2009 specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV and control cables with a rated voltage which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions. It is intended for use when testing cables not greater than 20 mm overall diameter.NOTE Cables of larger diameter should be tested using the apparatus, procedure and requirements of IEC 60331-1. This standard describes the means of test specimen preparation, the continuity checking arrangements, the electrical testing procedure, the method of burning the cables and the method of shock production, and gives requirements for evaluating test results. Annex A provides the method of verification of the burner and control system used for the test. Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this standard. It has the status of a horizontal standard in accordance with IEC Guide 104.
DevelopmentNote |
Stability Date: 2023. (04/2018)
|
DocumentType |
Standard
|
Pages |
49
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
AS/NZS IEC 60331.2:2017 | Identical |
IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 60331-3:2018 RLV | Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 60702-1:2002/A1:2015 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES (IEC 60702-1:2002/A1:2015) |
I.S. EN 60702-1:2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
IEC 60331-3:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure |
IEC 60092-353:2016 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
IEC 60092-376:2017 RLV | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
UNE-IEC 60092-353:2017 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
UNE-IEC 60092-350:2015 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
16/30342023 DC : 0 | BS EN 60331-1 - TESTS FOR ELECTRIC CABLES UNDER FIRE CONDITIONS - CIRCUIT INTEGRITY - PART 1: TEST METHOD FOR FIRE WITH SHOCK AT A TEMPERATURE OF AT LEAST 830 DEGREES C FOR CABLES OF RATED VOLTAGE UP TO AND INCLUDING 0,6/1,0 KV AND WITH AN OVERALL DIAMETER EXCEEDING 20 MM |
BS EN 60702-1 : 2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
IEC 60331-1:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm |
IEC 60092-353:2016 RLV | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
UNE-IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 60092-350:2014 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
IEC 60702-1:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables |
C22.2 NO. 245-17 | Marine shipboard cable |
IEC 60331-1:2018 RLV | Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
IEC 60331-1:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm |
IEC 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
IEC 61034-1:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus |