IEC 60432-3:2012
Current
The latest, up-to-date edition.
Incandescent lamps - Safety specifications - Part 3: Tungsten halogen lamps (non-vehicle)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
04-07-2012
FOREWORD
1 General
2 Requirements
3 Assessment
Annex A (normative) - Symbols
Annex B (normative) - Method of testing the gas-pressure
Annex C (informative) - Information for luminaire design
Annex D (normative) - Conditions of compliance for design
tests
Annex E (informative) - Bulb wall temperature measurement
Annex F (normative) - Induced failure test
Bibliography
IEC 60432-3:2012 specifies the safety requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications:
- projection (including cinematograph and still projection),
- photographic (including studio),
- floodlighting,
- special purpose,
- general purpose,
- stage lighting.
This second edition of IEC 60432-3 cancels and replaces the first edition published in 2002, Amendment 1 (2005) and Amendment 2 (2008). The main changes with respect to the previous edition are as follows:
- adapting the cold fill pressure requirements and tests for self-shielded lamps to the state of the technology,
- introduction of requirements to fully cover photobiological safety according to IEC 62471.
Committee |
TC 34/SC 34A
|
DevelopmentNote |
Stability Date: 2025. (09/2017)
|
DocumentType |
Standard
|
Pages |
65
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes | |
UnderRevision |
Standards | Relationship |
NF EN 60432-3 : 2013 | Identical |
NEN EN IEC 60432-3 : 2013 | Identical |
DIN EN 60432-3 : 2013 | Identical |
UNE-EN 60432-3:2013 | Identical |
CEI EN 60432-3 : 2013 | Identical |
EN 60432-3:2013 | Identical |
VDE 0715-11 : 2013 | Identical |
BS EN 60432-3:2013 | Identical |
PN EN 60432-3 : 2013 | Identical |
BS EN 60630 : 1999 | MAXIMUM LAMP OUTLINERS FOR INCANDESCENT LAMPS |
IEC 60079-7:2015+AMD1:2017 CSV | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
EN IEC 60079-7:2015/A1:2018 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017) |
EN 62838:2016/AC:2017-11 | LEDSI LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATIONS |
PD IEC/TR 62471-2:2009 | Photobiological safety of lamps and lamp systems Guidance on manufacturing requirements relating to non-laser optical radiation safety |
CEI 34-119 : 2010 | GUIDE FOR LUMINAIRE DESIGN - INFORMATION FOR A SAFE AND CORRECT OPERATION OF THE LIGHT SOURCES |
BS EN 60079-7 : 2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015) |
BS EN 60357 : 2003 | TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS (IEC 60357:2002, MODIFIED) |
I.S. EN 60630:2000 | MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS |
CSA C22.2 No. 60079-7 : 2016 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC TR 62471-2:2009 | Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety |
ANSI C78.1460 : 2004(R2015) | American National Standard for Electric Lamps—Single-Ended Tungsten-Halogen Lamps GZ9.5 Base, T6 Bulb, 36.5mm LCL, 76.2mm MOL with Proximity Reflector |
14/30278882 DC : 0 | BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
CEI 76-10 : 2011 | PHOTOBIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS - PART 2: GUIDANCE ON MANUFACTURING REQUIREMENTS RELATING TO NON-LASER OPTICAL RADIATION SAFETY |
EN 60598-1:2015/A1:2018 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
BS EN 60598-1:2015 | Luminaires General requirements and tests |
13/30281739 DC : 0 | BS EN 62838 - SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATION |
08/30175845 DC : DRAFT JAN 2008 | BS IEC 62471-2 - PHOTO BIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS - PART 2: GUIDANCE ON MANUFACTURING REQUIREMENTS RELATING TO NON-LASER OPTICAL RADIATION SAFETY |
15/30333848 DC : 0 | BS EN 60357:2003/PRAA:2015 - TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS |
I.S. EN 60598-1:2015 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNE-EN 60598-1:2015 | Luminaires - Part 1: General requirements and tests |
I.S. EN 60357:2003 | TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS |
BS EN 62838:2016 | LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. Safety specifications |
UNE-EN 62838:2016 | LEDsi lamps for general lighting services with supply voltages not exceeding 50 v a.c. r.m.s. or 120 v ripple free D.C. - Safety specifications |
12/30266672 DC : 0 | BS EN 60598-1 ED 8.0 - LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
08/30189882 DC : DRAFT SEP 2008 | BS EN 60630:1999+A6 - MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS |
I.S. EN 60079-7:2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
I.S. EN 62838:2016 | LEDSI LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATIONS |
UNE-EN 60079-7:2016 | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
IEC 60630:2005 CSV | Maximum lamp outlines for incandescent lamps |
EN 60630:1998/A7:2015 | MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS (IEC 60630:1994/A7:2014, MODIFIED) |
EN 60357:2003/A11:2016 | TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS |
CSA E60598.1 : 2016 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
CEI EN IEC 62471-7:2024 | Photobiological safety of lamps and lamp systems. Part 7: Light sources and luminaires primarily emitting visible radiation |
IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV | Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes |
IEC 60061-3:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges |
IEC 60682:1980 | Standard method of measuring the pinch temperature of quartz-tungsten-halogen lamps |
IEC 60838-1:2016+AMD1:2017 CSV | Miscellaneous lampholders - Part 1: General requirements and tests |
IEC TR 62471-2:2009 | Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety |
IEC 60050-845:1987 | International Electrotechnical Vocabulary (IEV) - Part 845: Lighting |
IEC 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
IEC 60061-4:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 4: Guidelines and general information |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 62471:2006 | Photobiological safety of lamps and lamp systems |
AS/NZS 62838:2020 | LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. - Safety specifications (IEC 62838:2015 (ED.1.0)/COR1:2017, MOD) |
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV | Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes |
IEC 60335-2-56:2002+AMD1:2008+AMD2:2014 CSV | Household and similar electrical appliances - Safety - Part 2-56:Particular requirements for projectors and similar appliances |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.