IEC 60853-2:1989

Current

Current

The latest, up-to-date edition.

Calculation of the cyclic and emergency current rating of cables. Part 2: Cyclic rating of cables greater than 18/30 (36) kV and emergency ratings for cables of all voltages

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

30-09-1989

€311.90
Excluding VAT

Foreword
Preface
Section One - Background
Clause
1. Introduction and scope
    1.1 General
    1.2 Inclusion of cable thermal capacitance
    1.3 Conditions where thermal capacitance can
         be neglected
    1.4 Guide to clauses applicable to particular
         types of cable
         1.4.1 Transient calculation and emergency rating
         1.4.2 Cyclic rating
2. Symbols
3. Layout of this standard
Section Two - Transient Temperature Response
4. Transient temperature response to a step function of
    current
    4.1 General aspects
         4.1.1 Background
         4.1.2 Criteria for the attainment factor to be
                unity
         4.1.3 Representation of the cable
         4.1.4 Criteria for selecting the thermal circuit
    4.2 Calculation of partial transients for long
         durations (>1/3T Q) and cyclic rating
         4.2.1 Representation of the dielectric
         4.2.2 Representation of the cable
         4.2.3 Calculation of cable partial transient
         4.2.4 Calculation of cable environment partial
                transient
    4.3 Calculation of partial transients for short
         duration (<1/3T Q)
         4.3.1 Representation of the dielectric
                (single and 3-core cables)
         4.3.2 Representation of the cable
         4.3.3 Calculation of cable partial transient
         4.3.4 Calculation of cable environment partial
                transient
    4.4 Calculation of the complete temperature transient
         4.4.1 Transient temperature response
         4.4.2 Correction to transient temperature
                response for variation in conductor losses
                with temperature (emergency ratings only)
         4.4.3 Transient temperature response caused by
                sudden application of voltage (transient
                due to dielectric loss)
Section Three - Cyclic Ratings
5. Computation of the cyclic rating factor (M)
    5.1 General
    5.2 Calculation of cyclic rating factor (including
         cable thermal capacitance)
         5.2.1 Any load cycle of known shape
         5.2.2 Flat top load cycle
         5.2.3 Load cycle of unknown shape but with a
                known loss-load (mu)
6. Calculation of loss-load factor (mu)
7. Calculation of OR(i)/OR(x)
    7.1 Single isolated 3-core cable
    7.2 Single isolated circuit
    7.3 Group of "N" cables with equal losses; cables or
         ducts not touching
    7.4 Group of circuits, each of three single-core identical
         touching cables or ducts, all cables having equal losses
Section Four - Emergency Ratings
8. Calculation of emergency ratings
    8.1 Thermally isolated circuits
    8.2 Groups of circuits
    8.3 Correction to transient temperature response to take
         account of variation in conductor losses with temperature
9. Bibliography
Appendix A - Reduction of a multiple thermal circuit to
one having two sections
Appendix B - Transient average temperature variation
through dielectric or through oil filling in pipes
Appendix C - Method for dealing with different soil
resistivities, thermal diffusivities and depths of
laying
Appendix D - Diffusivity of soil
Appendix E - Physical constants of materials
Appendix F - Examples

Gives manual methods for calculating cyclic rating factors for cables whose internal thermal capacitance cannot be neglected; in general this applies to cables for voltages greater than 18/30 (36) kV. It also gives a method for calculating the emergency rating for cables of any voltage.

Committee
TC 20
DevelopmentNote
Stability Date: 2020. (10/2012)
DocumentType
Standard
Pages
121
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
NEN IEC 60853-2 : 2007 AMD 1 2008 Identical
UNE 21191-2:1992 Identical

BS IEC 60287-2-1:2015 Electric cables. Calculation of the current rating Thermal resistance. Calculation of thermal resistance
IEC 60853-3:2002 Calculation of the cyclic and emergency current rating of cables - Part 3: Cyclic rating factor for cables of all voltages, with partial drying of the soil
UNE 211067-1:2017 Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 400 kV (Um = 420 kV). Part 1: Test methods and requirements.
IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
BS IEC 62895:2017 High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements
14/30290103 DC : 0 BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS
IEC 60840:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements
PD IEC/TR 62095:2003 Electric cables. Calculation of current rating. Cable current rating calculations using finite element method
03/302218 DC : DRAFT MAY 2003 IEC TR 62095 ED.1 - ELECTRIC CABLES - CALCULATION OF CURRENT RATING - CABLE CURRENT RATING CALCULATIONS USING FINITE ELEMENT METHOD
IEC 60287-2-1:2015 RLV Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance
IEC TR 62095:2003 Electric cables - Calculations for current ratings - Finite element method
BS IEC 60853-3:2002 Calculation of the cyclic and emergency current rating of cables Cyclic rating factor for cables of all voltages, with partial drying of the soil
I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
UNE 211632-1:2017 Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 1: Requirements and test methods
00/243632 DC : 0 IEC/TR 62095 - CURRENT RATING CALCULATIONS USING FINITE ELEMENT METHOD
BS 7450:1991 Method for determination of economic optimization of power cable size

IEC 60853-3:2002 Calculation of the cyclic and emergency current rating of cables - Part 3: Cyclic rating factor for cables of all voltages, with partial drying of the soil

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.