IEC 60853-2:1989
Current
The latest, up-to-date edition.
Calculation of the cyclic and emergency current rating of cables. Part 2: Cyclic rating of cables greater than 18/30 (36) kV and emergency ratings for cables of all voltages
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-09-1989
Foreword
Preface
Section One - Background
Clause
1. Introduction and scope
1.1 General
1.2 Inclusion of cable thermal capacitance
1.3 Conditions where thermal capacitance can
be neglected
1.4 Guide to clauses applicable to particular
types of cable
1.4.1 Transient calculation and emergency rating
1.4.2 Cyclic rating
2. Symbols
3. Layout of this standard
Section Two - Transient Temperature Response
4. Transient temperature response to a step function of
current
4.1 General aspects
4.1.1 Background
4.1.2 Criteria for the attainment factor to be
unity
4.1.3 Representation of the cable
4.1.4 Criteria for selecting the thermal circuit
4.2 Calculation of partial transients for long
durations (>1/3T Q) and cyclic rating
4.2.1 Representation of the dielectric
4.2.2 Representation of the cable
4.2.3 Calculation of cable partial transient
4.2.4 Calculation of cable environment partial
transient
4.3 Calculation of partial transients for short
duration (<1/3T Q)
4.3.1 Representation of the dielectric
(single and 3-core cables)
4.3.2 Representation of the cable
4.3.3 Calculation of cable partial transient
4.3.4 Calculation of cable environment partial
transient
4.4 Calculation of the complete temperature transient
4.4.1 Transient temperature response
4.4.2 Correction to transient temperature
response for variation in conductor losses
with temperature (emergency ratings only)
4.4.3 Transient temperature response caused by
sudden application of voltage (transient
due to dielectric loss)
Section Three - Cyclic Ratings
5. Computation of the cyclic rating factor (M)
5.1 General
5.2 Calculation of cyclic rating factor (including
cable thermal capacitance)
5.2.1 Any load cycle of known shape
5.2.2 Flat top load cycle
5.2.3 Load cycle of unknown shape but with a
known loss-load (mu)
6. Calculation of loss-load factor (mu)
7. Calculation of OR(i)/OR(x)
7.1 Single isolated 3-core cable
7.2 Single isolated circuit
7.3 Group of "N" cables with equal losses; cables or
ducts not touching
7.4 Group of circuits, each of three single-core identical
touching cables or ducts, all cables having equal losses
Section Four - Emergency Ratings
8. Calculation of emergency ratings
8.1 Thermally isolated circuits
8.2 Groups of circuits
8.3 Correction to transient temperature response to take
account of variation in conductor losses with temperature
9. Bibliography
Appendix A - Reduction of a multiple thermal circuit to
one having two sections
Appendix B - Transient average temperature variation
through dielectric or through oil filling in pipes
Appendix C - Method for dealing with different soil
resistivities, thermal diffusivities and depths of
laying
Appendix D - Diffusivity of soil
Appendix E - Physical constants of materials
Appendix F - Examples
Gives manual methods for calculating cyclic rating factors for cables whose internal thermal capacitance cannot be neglected; in general this applies to cables for voltages greater than 18/30 (36) kV. It also gives a method for calculating the emergency rating for cables of any voltage.
Committee |
TC 20
|
DevelopmentNote |
Stability Date: 2020. (10/2012)
|
DocumentType |
Standard
|
Pages |
121
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NEN IEC 60853-2 : 2007 AMD 1 2008 | Identical |
UNE 21191-2:1992 | Identical |
BS IEC 60287-2-1:2015 | Electric cables. Calculation of the current rating Thermal resistance. Calculation of thermal resistance |
IEC 60853-3:2002 | Calculation of the cyclic and emergency current rating of cables - Part 3: Cyclic rating factor for cables of all voltages, with partial drying of the soil |
UNE 211067-1:2017 | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 400 kV (Um = 420 kV). Part 1: Test methods and requirements. |
IEC 62067:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements |
BS IEC 62895:2017 | High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements |
14/30290103 DC : 0 | BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS |
IEC 60840:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements |
PD IEC/TR 62095:2003 | Electric cables. Calculation of current rating. Cable current rating calculations using finite element method |
03/302218 DC : DRAFT MAY 2003 | IEC TR 62095 ED.1 - ELECTRIC CABLES - CALCULATION OF CURRENT RATING - CABLE CURRENT RATING CALCULATIONS USING FINITE ELEMENT METHOD |
IEC 60287-2-1:2015 RLV | Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance |
IEC TR 62095:2003 | Electric cables - Calculations for current ratings - Finite element method |
BS IEC 60853-3:2002 | Calculation of the cyclic and emergency current rating of cables Cyclic rating factor for cables of all voltages, with partial drying of the soil |
I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
UNE 211632-1:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 1: Requirements and test methods |
00/243632 DC : 0 | IEC/TR 62095 - CURRENT RATING CALCULATIONS USING FINITE ELEMENT METHOD |
BS 7450:1991 | Method for determination of economic optimization of power cable size |
IEC 60853-3:2002 | Calculation of the cyclic and emergency current rating of cables - Part 3: Cyclic rating factor for cables of all voltages, with partial drying of the soil |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.