IEC 61010-2-061:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-09-2022
English - French
10-03-2015
FOREWORD
1 Scope and object
2 Normative references
3 Terms and Definitions
4 Tests
5 Marking and documentation
6 Protection against electric shock
7 Protection against mechanical hazards
8 Resistance to mechanical stresses
9 Protection against the spread of fire
10 Equipment temperature limits and resistance to heat
11 Protection against HAZARDS from fluids
12 Protection against radiation, including laser sources,
and against sonic and ultrasonic pressure
13 Protection against liberated gases and substances,
explosion and implosion
14 Components and subassemblies
15 Protection by interlocks
16 HAZARDS resulting from application
17 RISK Assessment
Annexes
Annex F (normative) - Routine tests
Annex H (informative) - Index of defined terms
Bibliography
IEC 61010-2-061:2015 applies to electrically powered laboratory atomic spectrometers with thermal atomization. It has the status of a group safety publication in accordance with IEC Guide 104. This third edition cancels and replaces the second edition published in 2003. It constitutes a technical revision and includes the following change from the second edition:
- exclusion of equipment, whose size and weight make unintentional movement unlikely, from the drop test in Clause 8.
- notes have been re-phrased according to ISO/IEC Directives.
This publication is to be read in conjunction with IEC 61010-1:2010.
Committee |
TC 66
|
DevelopmentNote |
Stability date: 2018. (03/2015)
|
DocumentType |
Standard
|
Pages |
29
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
OVE/ONORM EN 61010-2-061 : 2016 | Identical |
NBN EN 61010 2-061 : 2015 | Identical |
BS EN 61010-2-061:2015 | Identical |
PN EN 61010-2-061 : 2015-05 | Identical |
UNE-EN 61010-2-061:2004 | Identical |
NF EN 61010 2 061 : 2015 | Identical |
CEI EN 61010-2-061 : 2016 | Identical |
EN 61010-2-061:2015 | Identical |
NEN EN IEC 61010-2-061 : 2015 | Identical |
DIN EN 61010-2-061 : 2016 | Identical |
GOST IEC 61010-2-061 : 2011 | Identical |
SN EN 61010-2-061 : 2003 | Identical |
VDE 0411-2-061 : 2016 | Identical |
CSA C22.2 No. 1010.2.061 : 0 | Similar to |
UNE-EN 61010-2-061:2015 | Identical |
PNE-FprEN 61010-2-061 | Identical |
CSA Z15190 : 2005 : R2010 | MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY |
ISO 15190:2003 | Medical laboratories Requirements for safety |
IEC TR 61010-3-061:1999 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-061: Conformity verification report for IEC 61010-2-061, Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization |
BS ISO 15190:2003 | Medical laboratories. Requirements for safety |
CSA Z15190 : 2005 : R2015 | MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY |
CSA Z15190 : 2005 | MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.