IEC 61076-3-100:1999
Current
The latest, up-to-date edition.
Connectors for use in d.c., low-frequency analogue and digital high speed data applications - Part 3-100: Rectangular connectors with assessed quality - Detail specification for a range of shielded connectors with trapezoidal-shaped shells and non-removable ribbon contacts on a 1,27 mm double row
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
16-11-1999
Foreword
1 General Data
1.1 Recommended method of mounting
1.1.1 Minimum and maximum number of contacts
1.2 Rating and characteristics
1.3 Normative references
1.4 Marking
1.5 IEC type designation
1.6 Ordering information
2 Technical Data
2.1 General
2.2 Survey of styles and variants
2.3 Information on application
3 Dimensional Information
3.1 General
3.2 Isometric view and common features (with
locking devices)
3.3 Mating information
3.3.1 Contact arrangements
3.3.2 Mating face dimensions
3.3.3 Contact mating dimensions
3.4 Fixed connectors
3.4.1 Dimensions
3.4.2 Terminations
3.5 Free connectors
3.5.1 Dimensions
3.5.2 Terminations
3.6 Accessories
3.7 Mounting information
3.7.1 Hole pattern on printed boards
3.7.2 Panel cut-out dimensions
4 Characteristics
4.1 Climatic category
4.2 Electrical
4.2.1 Creepage and clearance distance
4.2.2 Voltage proof
4.2.3 Current-carrying capacity
4.2.4 Initial contact resistance
4.2.5 Initial insulation resistance
4.3 Mechanical
4.3.1 Mechanical operation
4.3.2 Insertion and withdrawal forces
5 Test schedule
5.1 General
5.2 Test schedules
5.2.1 Basic (minimum) test schedule
5.2.2 Full test schedule
6 Quality assessment procedures
6.1 Qualification approval testing
6.1.1 Method 1
6.1.2 Method 2
6.2 Quality conformance inspection
6.2.1 Lot-by-lot tests
6.2.2 Periodic tests
6.3 Delayed delivery, re-inspection
IEC 61076-3-100:1999 applies to a range of shielded two-part connectors with trapezoidal-shaped shells and non-removable ribbon contacts on 1,27 mm double rows. The fixed connectors are provided with a post either for dip solder (type A, B, C, D) or non-accessible insulation displacement terminations (type E). The free connectors are provided with non-accessible insulation displacement terminations.
DevelopmentNote |
Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
81
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NF EN 61076 3 100 : 2000 | Identical |
NEN EN IEC 61076-3-100 : 2000 | Identical |
I.S. EN 61076-3-100:2000 | Identical |
PN EN 61076-3-100 : 2002 | Identical |
SN EN 61076-3-100 : 2000 | Identical |
UNE-EN 61076-3-100:2000 | Identical |
BS EN 61076-3-100:2000 | Identical |
CEI EN 61076-3-100 : 2000 | Identical |
DIN EN 61076-3-100:2000-10 | Identical |
EN 61076-3-100:2000 | Identical |
PNE-EN 61076-3-100 | Identical |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60512-8:1993 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 8: Connector tests (mechanical) and mechanical tests on contacts and terminations |
IEC 61076-3:2008 | Connectors for electronic equipment - Product requirements - Part 3: Rectangular connectors - Sectional specification |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60512-6:1984 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 6: Climatic tests and soldering tests |
IEC 60512-7:1993 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 7: Mechanical operating tests and sealing tests |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60512-11-1:1995 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 11: Climatic tests - Section 1: Test 11a - Climatic sequence |
IEC 60512-4:1976 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 4: Dynamic stress tests |
IEC 60512-9:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 9: Miscellaneous tests |
IEC 60512-5:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests |
IEC 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60512-3:1976 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 3: Current-carrying capacity tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.