IEC 61076-3-117:2009
Current
The latest, up-to-date edition.
Connectors for electronic equipment - Product requirements - Part 3-117: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface - Variant 14 related to IEC 61076-3-106 - Push-pull coupling
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
29-04-2009
FOREWORD
1 Scope
2 General data
2.1 Normative references
2.2 Terms and definitions
3 Dimensional information
3.1 Common features
3.2 General
3.3 Contact arrangement of all connector types
3.4 IP65 and IP67 sealing
3.5 Dimensions, fixed connector
3.6 Dimensions, free connector
3.7 Termination and mounting information
3.7.1 General
3.7.2 Mounting information for fixed connector
4 Gauges
4.1 Connectors, IEC 60603-7 interface
5 Characteristics
5.1 Climatic category
5.2 Electrical characteristics
5.2.1 Clearance and creepage distances
5.2.2 Voltage proof
5.2.3 Current-carrying capacity
5.2.4 Mating cycles with power applied
5.2.5 Initial contact resistance
5.2.6 Input to output resistance
5.2.7 Resistance unbalance
5.2.8 Initial insulation resistance
5.3 Transmission characteristics
5.3.1 General
5.4 Mechanical
5.4.1 Mechanical operation
5.4.2 Effectiveness of connector coupling devices
transversal
5.4.3 Effectiveness of connector coupling devices
5.4.4 Engagement and separation forces
6 Test schedule
6.1 General
6.2 Test procedures and measuring methods
6.3 Preconditioning
6.4 Wiring and mounting of specimens
6.4.1 Wiring
6.4.2 Mounting
6.5 Arrangement for contact resistance test
6.6 Arrangement for dynamic stress tests (test phase AP2)
6.7 Basic (minimum) test schedule
6.8 Full test schedule
6.8.1 General
6.8.2 Test group P - Preliminary
6.8.3 Test group P
6.8.4 Test group AP
6.8.5 Test group BP
6.8.6 Test group CP
6.8.7 Test group DP - Electrical load and temperature
6.8.8 Test group EP - Signal integrity
IEC 61076-3-117:2009 covers rectangular protective housings with push-pull coupling for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-41, IEC 60603-7-5, IEC 60603-7-51, IEC 60603-7-7 and IEC 60603-7-71 to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments. Common mating configurations for all variants of the 8-way shielded and unshielded connectors are defined in IEC 60603-7.
Committee |
TC 48/SC 48B
|
DevelopmentNote |
Supersedes IEC PAS 61076-3-117. (04/2009) Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
37
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 61076-3-117 : 2009 | Identical |
NEN EN IEC 61076-3-117 : 2009 | Identical |
I.S. EN 61076-3-117:2009 | Identical |
PN EN 61076-3-117 : 2009 | Identical |
UNE-EN 61076-3-117:2009 | Identical |
BS EN 61076-3-117:2009 | Identical |
CEI EN 61076-3-117 : 2010 | Identical |
EN 61076-3-117:2009 | Identical |
DIN EN 61076-3-117:2010-01 | Identical |
PNE-FprEN 61076-3-117 | Identical |
CEI EN 61754-24-11 : 2010 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - FIBRE OPTIC CONNECTOR INTERFACES - PART 24-11: TYPE SC-RJ CONNECTORS WITH PROTECTIVE HOUSINGS BASED ON IEC 61076-3-117 |
I.S. EN 61754-24-11:2009 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - FIBRE OPTIC CONNECTOR INTERFACES - PART 24-11: TYPE SC-RJ CONNECTORS WITH PROTECTIVE HOUSINGS BASED ON IEC 61076-3-117 |
I.S. EN 61918:2013 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES |
15/30332712 DC : 0 | BS EN 61076-3-123 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-123: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR HYBRID CONNECTORS FOR INDUSTRIAL ENVIRONMENTS, FOR POWER SUPPLY AND FIBRE OPTIC DATA TRANSMISSION, WITH PUSH-PULL LOCKING |
IEC 61918:2013 | Industrial communication networks - Installation of communication networks in industrial premises |
BS EN 61918:2013 | Industrial communication networks. Installation of communication networks in industrial premises |
ISO/IEC 14763-4:2018 | Information technology Implementation and operation of customer premises cabling Part 4: Measurement of end-to-end (E2E)-Links |
BS EN 61754-24-11:2009 | Fibre optic interconnecting devices and passive components. Fibre optic connector interfaces Type SC-RJ connectors with protective housings based on IEC 61076-3-117 |
IEC 61754-24-11:2009 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 24-11: Type SC-RJ connectors with protective housings based on IEC 61076-3-117 |
EN 61918:2013/AC:2014 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES (IEC 61918:2013, MODIFIED) |
11/30258071 DC : 0 | BS EN 61918 - INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES |
EN 61754-24-11:2009 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 24-11: Type SC-RJ connectors with protective housings based on IEC 61076-3-117 |
CEI EN IEC 61076-3-106:2024 | Connectors for electrical and electronic equipment - Product requirements - Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.