IEC 61391-2:2010
Current
The latest, up-to-date edition.
Ultrasonics - Pulse-echo scanners - Part 2: Measurement of maximum depth of penetration and local dynamic range
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, English - French
14-01-2010
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirement
5 Environmental conditions
6 Equipment and data required
7 Measurement methods
Annex A (informative) - Phantom for determining maximum
depth of penetration
Annex B (informative) - Local dynamic range using acoustical
test objects
Bibliography
IEC 61391-2:2010 defines terms and specifies methods for measuring the maximum depth of penetration and the local dynamic range of real time ultrasound B MODE scanners. The types of transducers used with these scanners include:
- mechanical probes;
- electronic phased arrays;
- linear arrays;
- curved arrays;
- two-dimensional arrays;
- three-dimensional scanning probes based on a combination of the above types.
All scanners considered are based on pulse-echo techniques. The test methodology is applicable for transducers operating in the 1 MHz to 15 MHz frequency range operating both in fundamental mode and in harmonic modes that extend to 15 MHz. However, testing of harmonic modes above 15 MHz is not covered by this standard.
Committee |
TC 87
|
DevelopmentNote |
A Bilingual edition has been published. (06/2010) Stability Date: 2022. (09/2017)
|
DocumentType |
Standard
|
Pages |
37
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
GOST R IEC 61391-2 : 2012 | Identical |
NF EN 61391-2 : 2011 | Identical |
NBN EN 61391-2 : 2010 | Identical |
NEN EN IEC 61391-2 : 2010 | Identical |
I.S. EN 61391-2:2010 | Identical |
PN EN 61391-2 : 2010 | Identical |
UNE-EN 61391-2:2010 | Identical |
BS EN 61391-2:2010 | Identical |
CEI EN 61391-2 : 2011 | Identical |
EN 61391-2:2010 | Identical |
DIN EN 61391-2:2010-09 | Identical |
PNE-FprEN 61391-2 | Identical |
PD IEC/TS 62736:2016 | Ultrasonics. Pulse-echo scanners. Simple methods for periodic testing to verify stability of an imaging system’s elementary performance |
DD IEC/TS 62558:2011 | Ultrasonics. Real-time pulse-echo scanners. Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR) |
IEC TS 62558:2011 | Ultrasonics - Real-time pulse-echo scanners - Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR) |
IEC TS 62791:2015 | Ultrasonics - Pulse-echo scanners - Low-echo sphere phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to a broad range of transducer types |
I.S. EN 61391-1:2006 | Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of system point-spread function response |
BS EN 61391-1 : 2006 | ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE |
PD IEC/TS 62791:2015 | Ultrasonics. Pulse-echo scanners. Low-echo sphere phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to a broad range of transducer types |
08/30177593 DC : DRAFT FEB 2008 | BS EN 62558 - ULTRASONIC - REAL-TIME PULSE-ECHO SCANNERS - PHANTOM AND METHOD FOR AUTOMATED EVALUATION AND PERIODIC TESTING OF 3-D DISTRIBUTIONS OF SIGNAL-TO-NOISE RATIO USING VOIDS |
IEC TS 62736:2016 | Ultrasonics - Pulse-echo scanners - Simple methods for periodic testing to verify stability of an imaging system's elementary performance |
IEC 61391-1:2006+AMD1:2017 CSV | Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of point-spread function response |
15/30330344 DC : 0 | BS EN 61391-1+A1 - ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF POINT-SPREAD FUNCTION RESPONSE |
14/30250927 DC : 0 | BS IEC 62736 - ULTRASONICS - PULSE-ECHO SCANNERS - QUALITY CONTROL OF DIAGNOSTIC MEDICAL ULTRASOUND SYSTEMS - SIMPLE METHODS FOR PERIODIC TESTING TO VERIFY STABILITY OF AN IMAGING SYSTEM'S ELEMENTARY PERFORMANCE |
EN 61391-1:2006/A1:2017 | ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE (IEC 61391-1:2006/A1:2017) |
IEC 62127-1:2007+AMD1:2013 CSV | Ultrasonics - Hydrophones - Part 1: Measurement and characterizationof medical ultrasonic fields up to 40 MHz |
IEC 61161:2013 | Ultrasonics - Power measurement - Radiation force balances and performance requirements |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 60050-802:2011 | International Electrotechnical Vocabulary (IEV) - Part 802: Ultrasonics |
IEC 61391-1:2006+AMD1:2017 CSV | Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of point-spread function response |
IEC 60050-801:1994 | International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics |
NEMA PS 3.1:2017A | DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE (DICOM) - PART 1: INTRODUCTION AND OVERVIEW |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.